Mechanical parts

 

Check the correct working of the mechanical parts and, if needed, replace them. Make sure the projector is not mechanically 
damaged. If necessary, replace the worn parts. 

Electrical components

 

Check all electrical connections, in particular for correct grounding and correct attachment of all extractable connectors. Press the 
connectors if necessary and reposition as before. 
 

11.3 Fuses: 

 
Reflection has an automatic fuse that in most cases does not need to be replaced. 

12. F.A.Q. and answers  

 
The following list shows common issues that may be simply solved. If issues persist, the unit must be repaired by qualified 
personnel or just contact your Coemar service near you. 

Question 

Possible cause 

Suggested solution 

Reflection does not power on. 

-

Projector not powered on:  

 
 
 

1-Make sure the power cord is plugged in 
or test the input voltage. 
 

Reflection does not answer to DMX 
signal. 

DMX signal may not reach Reflection . 

Inspect the cable connection, correct 
poor connections or inefficient repair or 
replace damaged cables. 
Check DMX address of the unit. 

I set Reflection as MASTER unit but it 
does not perform any program. 

1-There is another unit set as MASTER. 
2-The DMX signal is present. 
3-Any program has not been set. 

1-Search for the other MASTER unit and 
set it as SLAVE 
2-Remove eventual DMX patch. 
3-Set a program on the MASTER unit. 

Reflection is not recognized by DR1 Plus. 

ID set to 0 or another unit in the chain is 
set with the same number.. 

Set an ID number different from 0 and 
from any other unit in the chain. 

 

 

 

Information on disposal of the equipment 

 

 

The equipment at the end of its useful life must be disposed of at an appropriate recycling center for 
waste electrical and electronic equipment. The treatment and disposal of environmentally friendly, helps 
prevent potential negative environmental and health and promote the reuse and / or recycling of 
materials making up the equipment. Illegal disposal by the user includes the application of administrative 
sanctions provided by law.

 

 

 

Summary of Contents for Reflection FullSpectrum

Page 1: ...Reflection FullSpectrum instruction manual manuale di istruzioni Version 1 0 DIS132 ...

Page 2: ...or in answering any technical enquiries with the utmost speed and accuracy Prendete nota nello spazio apposite dei dati relative al modello e al rivenditore del vostro Reflection questi dati ci permetteranno di assistervi con la massima rapidità e precisione WARNING the security of the fixture is granted only if these instructions are strictly followed therefore it is absolutely necessary to keep ...

Page 3: ...er 9 6 Control signal connections 10 6 1 Control signal connection by XLR5 plugs 10 7 Turning on the projector 11 7 1 DMX address of the unit 11 7 2 DMX functions 12 8 Display panel functions 15 8 1 Quick guide to menù 15 8 2 Rapid count 15 8 3 Main function menu Main functions 16 8 4 Tests and measures Measures 18 8 5 Display settings Display Setup 19 8 6 User settings Mode 19 8 7 Connecting DR1 ...

Page 4: ...the mains adhere strictly to the guidelines outlined in this manual 3 The level of technology of Reflection requires the use of specialised personnel for all service applications refer all work to your authorised Coemar service centre 4 A good earth connection is essential for the proper functioning of the projector Never connect the fixture if there is no earth connection 5 Mains cables must not ...

Page 5: ...erature 35 C 95 F Weight 12 5 Kg 27 5 lbs Grado di protezione IP20 The innovative core of Reflection consists of a reflection system with a source made of powerful leds in it which casts a compact beam in infinite colors combination without any defect that any other classic multi lens led projector gives Reflection has also an automatic zoom system that allows to modify the beam width 3 2 Dimensio...

Page 6: ...ctronic sector 8 Yoke lock handle 4 Cooling sector 9 Lower casing 5 Mirror 4 Installation 4 1 Mechanical installation Reflection may be floor mounted or hung from an appropriate structure in any position If hanging the fixture from a lighting truss or similar we recommend the use of an appropriate clamp B as shown in the following diagram B ...

Page 7: ...he standard yoke which can be opened for allow an adequate support for the floor 4 2 Safety chain When hanging Reflection we recommend the use of a safety chain affine to the body and to the suspension device The safety chain should be either a metal rope or a metal chain both suitably for the purpose In the case that the chain used is not producted by Coemar ensure that it can bear the weight of ...

Page 8: ...suit any frequency or voltage within this range 5 2 Connection to mains power Mains cable characteristics The mains cable provided is thermally resistant complying to the most recent International standards Note in case of cable replacement similar cable with comparable thermal resistant qualities must be used exclusively cable 3 X 1 5 ø external 10 mm rated 300 500V tested to 2 KV operating tempe...

Page 9: ...ins characteristics are within the recommended range for use with Reflection All cabling and connections should be carried out by suitably qualified personnel 6 Control signal connections 6 1 Control signal connection by XLR5 plugs The digital control signal is transmitted to the projector via a two pole cable screened as per International standards for the transmission of DMX 512 data The connect...

Page 10: ...it Each projector uses 12 DMX channels 16 bits mode for its complete operation and is controlled by a DMX 512 signal for further information see section 7 2 DMX functions DMX addressing When powered up initially each projector will show A001 which indicates DMX address 001 a projector thus addressed will respond to commands of channels 1 to 12 from your DMX 512 controller or from 1 to 8 at 8 bits ...

Page 11: ...English 12 7 2 DMX functions To set the configuration access the menu MAIN FUNCTIONS DMX CHANNELS 12 channels configuration ...

Page 12: ...English 13 ...

Page 13: ...English 14 8 channels configuration ...

Page 14: ... order to access the functions just press the menu button one after the other all the voices of the menu will be cyclically shown each time the key or will be pressed To select the desired function press enter 8 2 Rapid count By the display panel of Reflection It is possible to quickly change the various numbers displayed for the different functions in the following 3 manners 1 Pressing the or but...

Page 15: ... hours counter On Off enter Are you sure ID CODE It sets the ID number of the unit Use and buttons and ENTER to confirm Da 1 a n It allows to cast primary colors and check motor s functioning without dmx SIGNAL SAVE ALL stores all settings until next power on See for visualization It allows to choose primary colors and emulate classic CMY filter system in a large range of tones without dmx signal ...

Page 16: ...NE SCARLET RED 24 PRIMARY GREEN PRIMARY BLUE 80 RED SALMON 40 TURQUOISE 92 MEDIUM BLUE 83 DEEP SALMON 42 BLUE GREEN 93 BLUE INDIGO 59 LIGHT RED 26 LIGHT GREEN 88 CONGO BLUE 382 Save all WHITE 9000 K WHITE 7500 K WHITE 4500 K WHITE 3200 K CYAN TONE YELLOW TONE WHITE TONE CYAN 4307 YELLOW 4560 CYAN 4330 GALLO GOLD 316 CYAN 4390 YELLOW FLAME 18 CYAN 2005 ORANGE 23 MAGENTA 4715 MAGENTA 4730 MAGENTA 47...

Page 17: ...TE frequency of signal updating in milliseconds It shows the error message of the alarm in progress It shows the luminous efficiency of the RGBW leds It shows the led s life values in hours led life r led module life resettable led life life of total modules installed on the unit since now not resettable unit life life of the projector It shows the led s emission frequency It may be useful if freq...

Page 18: ...s one to decide number of seconds before turning off the display back light in case of inactivity OFF value leaves the backlight always on It allows setting up number of seconds buttons must be pressed in order to activate functions This function avoid activation of features if buttons are pressed accidentally It allows setting of brightness of display back light MODE DMX only MASTER SLAVE It rest...

Page 19: ...flection will not be recognized by DR1 and DR1 Plus Never assign the same ID to two or more units of a same DMX line This causes the failure of the system DR1 and DR1 Plus will display an error message For more information see the manual for DR1 or DR1 Plus 8 8 Electronic alignment of the leds The display panel of Reflection allows the electronic alignment of the leds this procedure is performed b...

Page 20: ...n BLUE min WHITE max RED max GREEN max WHITE max BLUE ZOOM Red leds alignment at minimum intensity Green leds alignment at minimum intensity Blue leds alignment at minimum intensity White leds alignment at minimum intensity Red leds alignment at maximum intensity Green leds alignment at maximum intensity Blue leds alignment at maximum intensity White leds alignment at maximum intensity Zoom motor ...

Page 21: ... present but frame too short the controller has not enough channels to control the projector Internal FAN The rear fan is damaged or stuck Turn off the unit then turn it on again and if the error persist contact your Coemar Service Center near you Radiator FAN The internal cooling fan is damaged or stuck Turn off the unit then turn it on again and if the error persist contact your Coemar Service C...

Page 22: ...rush or a common vacuum cleaner or a source of compressed air for removing dust For the cleaning of the housing use a soft cloth and a non aggressive cleaner Check that the internal fans and heat exchanger must be perfectly clean 11 2 Special controls How to top up the water tank to perform every 1500 hours 1 Open the upper casing of the unit by unscrewing the 4 screws 2 Locate the water tank whic...

Page 23: ...gnal may not reach Reflection Inspect the cable connection correct poor connections or inefficient repair or replace damaged cables Check DMX address of the unit I set Reflection as MASTER unit but it does not perform any program 1 There is another unit set as MASTER 2 The DMX signal is present 3 Any program has not been set 1 Search for the other MASTER unit and set it as SLAVE 2 Remove eventual ...

Page 24: ......

Page 25: ......

Page 26: ...2 A 46042 Castel Goffredo Mantova Italy ph 39 0376 77521 fax 39 0376 780657 info coemar com Coemar si riserva il diritto di apportare modifiche senza preavviso Coemar reserves the right to effect modifications without notification ...

Reviews: