9. Error messages
If a malfunction occurs,
Reflection
has a self-diagnostic system that will show the error message on the display. The following
table will explain in detail the most common errors. If, despite of suggested intervention, the problem persists, call the Coemar
Service center near you.
Error message
Description and suggested solution.
Eeprom Failure
The initial configuration settings are faulty or have been loaded incorrectly. The unit has loaded its default
configuration. Turn the unit off and on again and if the error persists, it means that the Eeprom is defective.
Refer to your Coemar service center for the servicing.
CFG data Failure
The electronics of the unit found problems in loading data from Eeprom: it does not load custom settings but
default factory settings. Contact your Coemar Service Center near you.
DMX address
The unit is not receiving all the DMX channels necessary for its operation. Check the DMX address and the
control console operation. Note that some controllers may not generate all 512 channels of signal.
DMX frame
DMX signal present but frame too short; the controller has not enough channels to control the projector.
Internal FAN
The rear fan is damaged or stuck. Turn off the unit then turn it on again and if the error persist contact your
Coemar Service Center near you.
Radiator FAN
The internal cooling fan is damaged or stuck. Turn off the unit then turn it on again and if the error persist
contact your Coemar Service Center near you.
Pump FAILURE
The pump of the cooling system is damaged or stuck. Turn off the unit then turn it on again and if the error
persist contact your Coemar Service Center near you.
Over TEMPERATURE
The light source has reached the maximum allowable temperature and so the unit shuts off . Check for water
level in the cooling circuit , check fans and pump’s functioning.
10.Accessories and spare parts
Reflection is a very versatile fixture, optional accessories for its customization are available under request:
Coemar order code
Description
CO002
4 blades barndoor
BC10001A000
Accessories holder
CO001
Standard size gel frame
All the components of
Reflection
are available as spare parts from your Coemar dealer or Service. Accurate description of the
fixture, model number and type will assist us in providing for your requirements in an efficient and effective manner
Summary of Contents for Reflection FullSpectrum
Page 1: ...Reflection FullSpectrum instruction manual manuale di istruzioni Version 1 0 DIS132 ...
Page 12: ...English 13 ...
Page 13: ...English 14 8 channels configuration ...
Page 24: ......
Page 25: ......