English
4) Locate the lampholder
D
5) Insert the lamp. The lamp is manufactured from quartz glass and should be handled with care; always adhere to the instruc-
tions supplied in the lamp’s packaging. Never touch the glass directly; use the tissue provided in the lamp’s packaging. The GY
9,5 lampholder is asymmetrical in construction, with one lamp pin larger than the other is. DO NOT USE UNDUE FORCE. In
case of difficulty, inspect for physical damage and then repeat the installation procedure.
6) The optimal gap between the lamp and the parabolic
reflector is around 2 to 3 mm. If this is not the case, rota-
te the two adjusting thumbscrews located at the rear of
the projector as indicated in the section of this manual
entitled
“Aligning the lamp in the optical path”
.
The lamp must under no circumstances come into
contact with the reflector or other components of
the optical system.
7) Reposition the lamp cover and replace the three screws
C
previously removed. Replace the housing
B
and refasten the
four screws
A
as per the original condition of the
ProSpot LX
.
Prior to switching on the projector with the new lamp installed, reset the lamp life counter as described in section
11
“Display panel functions”.
We recommend that replacement lamps be realigned in the optical path of the lamp so as to avoid any accidental
overheating of the internal components of the fixture. This procedure is described in the section of this manual entitled
“Aligning the lamp in the optical path”
.