8.4 Synchronising Panoramas without DMX 512 signal
Multiple
Panorama C
yc 1800
A
rchitectural
units may be interconnected in the absence of DMX 512 signal, operating
simply via the inbuilt programs within the
Panorama unit
.
All the
Panorama C
yc
1800’s
thus connected will operate simultaneously
with one unit acting as MASTER and all
subsequent units as a SLAVE.
The
Panorama C
yc 1800
A
rchitectural
which is to act as master should be selected according to ease of access for pro-
gramming purposes. Control signal is transmitted from Master to slave via 2 core ø0,5 screened cable.
Connection is serial, daisy-chaining units using the
DMX IN
and
DMX OUT
sockets located in the base of the
Panorama
C
yc 1800
A
rchitectural
.
1) insert the cables through the PG 9 entry sockets.
2) Connect as shown in the diagram below.
Connect the projectors by using the signal
from the “
master
” to connect to the first
slave, then from the first slave to the
second, and so on to a maximum of 10
projectors.
ATTENTION
:Ensure that all data conductors are isolated from one another and the metal housing of the connector.and
under no circumstances should any connection be made from the signal cable or the screening to the metal support of the
projector. Test that the cable is isolated prior to powering up the projector.
Should you need to connect more than 10 units we recommend that you use a suitable dmx
splitter box to achieve this.
These units are usually opto-isolated and may amplify and repeat the signal as required.
We recommend that any unused PG 9 entry sockets be sealed as previously described to main-
tain the integrity of the
Panorama C
yc 1800
A
rchitectural’s weather protection rating.
Prior to closing the base of the unit, we recommend that all the internal settings be carried
out (sections 10 to 14); do not forget to set the DMX address, any automated settings, auto-
mated programs and any other settings via the multifunction display panel as access to the
panel is only available when the cover is off.
Once these settings have been carried out, all internal junction boxes may be closed up to
seal them off as shown below.
master
slave
out
in
made in italy by
coemar
spa
Castel Goffredo (mn)
serial number
Alimentazione: collegare SOLO a coemar ballast 1800W.
Per accedere alle connessioni di potenza e segnale riferitevi al manuale di istruzioni.
Main power: connect to coemar ballast 1800W ONLY.
To acces to mains and signal connections pls. refer to the instructions manual.
ATTENZIONE!
ALTA TENSIONE ALL'INTERNO DELL'APPARECCHIO. TOGLIERE TENSIONE
PRIMA DI EFFETTUARE QUALSIASI OPERAZIONE.
UNA BUONA CONNESSIONE DI TERRA E' ESSENZIALE.
WARNING!
HIGH VOLTAGE INSIDE. DISCONNECT FROM POWER SUPPLY
BEFORE OPENING. A GOOD GROUND CONNECTION IS ESSENTIAL.
pin1: gnd
pin2: data-
pin3: data+
pin4: optional-
pin5: o
dmx 512
in
out
3
2
1
AUto
auto sequence
MA.SL
link between fixture
AUSP
auto speed
AUdL
auto delay
diMM
dimmer
coLr
colour speed
LAMP
lamp function
tESt
single ch. test function
rESE
reset
rAtE
DMX speed
HoUr
working time (in hour)
LIFE
lamp life (in hours)
on
MASt
master
0000
time speed (m=min. s=sec.)
0000
number of frames
Strd
standard
Strd
standard
Strd
standard
oFF
slav
slave
01
to ...
01
to ...
SLoU
slow
SLoU
slow
Strd
standard
t01
to
t04
Set functions (function display)
menu
enter
enter
1
dimmer
2
cyan
3
magenta
4
yellow
5
function
Individual channel assignement
factory set main at:
208V
230V
240V
115V
out
in
made in italy by
coemar
spa
Castel Goffredo (mn)
serial number
Alimentazione: collegare SOLO a coemar ballast 1800W.
Per accedere alle connessioni di potenza e segnale riferitevi al manuale di istruzioni.
Main power: connect to coemar ballast 1800W ONLY.
To acces to mains and signal connections pls. refer to the instructions manual.
ATTENZIONE!
ALTA TENSIONE ALL'INTERNO DELL'APPARECCHIO. TOGLIERE TENSIONE
PRIMA DI EFFETTUARE QUALSIASI OPERAZIONE.
UNA BUONA CONNESSIONE DI TERRA E' ESSENZIALE.
WARNING!
HIGH VOLTAGE INSIDE. DISCONNECT FROM POWER SUPPLY
BEFORE OPENING. A GOOD GROUND CONNECTION IS ESSENTIAL.
pin1: gnd
pin2: data-
pin3: data+
pin4: optional-
pin5: o
dmx 512
in
out
3
2
1
AUto
auto sequence
MA.SL
link between fixture
AUSP
auto speed
AUdL
auto delay
diMM
dimmer
coLr
colour speed
LAMP
lamp function
tESt
single ch. test function
rESE
reset
rAtE
DMX speed
HoUr
working time (in hour)
LIFE
lamp life (in hours)
on
MASt
master
0000
time speed (m=min. s=sec.)
0000
number of frames
Strd
standard
Strd
standard
Strd
standard
oFF
slav
slave
01
to ...
01
to ...
SLoU
slow
SLoU
slow
Strd
standard
t01
to
t04
Set functions (function display)
menu
enter
enter
1
dimmer
2
cyan
3
magenta
4
yellow
5
function
Individual channel assignement
factory set main at:
208V
230V
240V
115V
Ad altri
Panorama C
yc
A
rchitectural (Slave)
Connect to other
Panorama C
yc
A
rchitectural (Slave)
Schermatura
Schermatura
Ø 0,5
Ø 0,5
Al prossimo
Panorama
1
2
3
Non collegato
Panorama 1800 Architectural
Slave
3
2
1
Dmx 512 Out
3
2
1
Dmx 512 in
Panorama 1800 Architectural
Slave
3
2
1
Dmx 512 Out
3
2
1
Dmx 512 in
Panorama 1800 Architectural
Master
3
2
1
Dmx 512 Out
3
2
1
Dmx 512 in
Ø 0,5
Ø 0,5