English
21
WARNING !
Each time you change the lamp, we recommend the following be carried out:
• realign the lamp in the optical path to avoid overheating filters and/or effects
• reset the lamp’s odometer
9.2 Aligning the lamp in the optical path.
Aligning the lamp in the optical system is achieved via the 3 adjusters at the rear of the projector. This procedure should be under-
taken to maximise output, to avoid the possible overheating of the internal components due to the incorrect focusing of the beam onto
components not predisposed to high temperature. It is extremely important to obtain a uniform distribution of light on all beams.
Alignment procedure
Alignment is carried out by using the 3 screws A, B and C showed in the picture below. The lamp should be on, black-out and dimmer
fully open, and no colours selected. If the lamp is not correctly aligned, a hot-spot will be readily noticeable. Using the 3 adjusters in
unison, you will need to bring the hot-spot to the most central part of the beam possible and then flatten the beam to maximum unifor-
mity. The combined regulation of the three adjusters allows horizontal, vertical and axial regulation of the lamp.
10. Operating on inside groups
Infinity Spot S allows extraction of both gobos and colour changer assemblies in order to facilitate inspection, gobos replacing and
cleanning of coloured filters and lens.
WARNING !
The following procedures should be undertqaken by qualified and experience technical personnel.
handle with extreme care.
Always disconnect all cables before proceeding and ensure that the unit is sufficiently cool.
10.1 How to open the projector.
Using an appropriate screwdriver, remove the screws “A” which fix the housings and remove it.
To identify which part of the projector must be removed, position the unit so that the labels of the lamp holder group can be read and
are in the upright position. Now lock the unit by the locking device and remove the upper cover.