iCyc 250
may operate in 3 different modes:
8.1 Automated operation
8.2 Using DMX 512 signal
8.3 Synchronising iCyc 250 without DMX 512 signal.
Follow the instructions below which relate to your particular application:
8.1 Automated operation “solo”
iCyc 250 may operate in stand alone mode in the absence of control signal, using pre-programmed colour
changing sequence which can be activated by the multi-function panel on the unit.
No incoming signal to the XLR3 sockets should be connected and these sockets may be isolated by disconnecting.the internal ter-
minals labelled DMX IN and DMX OUT. We recommend that the XLR 3 sockets be isolated by using suitably sheathed weather-proof
dummy plugs.
8.2 Using DMX 512 signal
Control signal is digital, and is transmitted via two pair screened ø0.5mm cable.
Connection is serial, utilising the XLR 3 sockets located on the base of the
iCyc 250
.
coemar
supplies with the unit XLR 3 connectors with an IP 67 protection rating; use only similar plugs for the connection of signal
to the unit, thereby ensuring that the protection rating of the unit is maintained.
coemar
code for the IP 67 rated XLR3 socket is ME 34
coemar
code for the IP 67 rated XLR3 plug is ME 35
We recommend isolating the XLR 3 socket which terminates you dmx daisy chain.
To isolate the connector (which is the only one without a plug inserted) you may internally disconnect the cabling from the socket
indicated by the DMX OUT sticker.
signal connection
Connection is to international standards:
pin 1= gnd
pin 2= data –
pin 3= data +
Ensure that all data conductors are isolated
from one another and the metal housing of
the connector.
Note: the housing of the XLR 3 must
be isolated.
Pin 1 should never be connected to mains power.
Should your
DMX 512
controller output via an XLR 5 socket, the polarity of pins 1, 2 and 3 must be maintained and pins 4 and 5
should remain unconnected.
function display
serial number
factor
y set main at:
100V
115V
208V
230V
240V
50Hz
60Hz
made in italy by
coemar
spa
Castel Goffredo (mn)
Warning!
High voltage inside. Caution: hot lamp. Disconnect from power supply before opening.
A good ground connection is essential. Case is very hot. Do not install on flammable
surfaces. Min. Distance from flammable materials to all exterior surfaces: 0,5m. Important
safety information, see instruction manual before use.
menu
enter
+
DMX
OUT
DMX IN
230v
ie max: 2A
ie: 1,6A
115v
ie max: 4,2A
ie: 3,2A
max temp
ext:
150
°
C
ta max:
40
°
C
cos
ϕ
:
0,9
IP 20
weight:
18,4 kg
alto/top
2 m
2 m
5AT @230V
8AT @115V
POWER
3 pin XLR 3/M
3 pin XLR 3/F
out
in
in
function display
serial number
factor
y set main at:
100V
115V
208V
230V
240V
50Hz
60Hz
made in italy by
coemar
spa
Castel Goffredo (mn)
Warning!
High voltage inside. Caution: hot lamp. Disconnect from power supply before opening.
A good ground connection is essential. Case is very hot. Do not install on flammable
surfaces. Min. Distance from flammable materials to all exterior surfaces: 0,5m. Important
safety information, see instruction manual before use.
menu
enter
+
DMX O
U
T
DMX IN
230v
ie max: 2A
ie: 1,6A
115v
ie max: 4,2A
ie: 3,2A
max temp
ext:
150
°
C
ta max:
40
°
C
cos
ϕ
:
0,9
IP 20
weight:
18,4 kg
alto/top
2 m
2 m
5AT @230V
8AT @115V
POWER
Controller
DMX 512
OUT
3
2
1
8. Signal connection
8
English