cabling
The mains cable provided is thermally resistant, complying to the most recent international standards.
NB:
In case of cable replacement, similar cable with comparable thermal resistant qualities must be used exclusively (cable 3x1.5 ø exter-
nal 10 mm, rated 300/500V, tested to 2KV, operating temperature -40° +180°.
coemar
cod. CV5309).
mains connection
iCyc 250
can operate at voltages from 100V-115V-208V-230V-240V at 50 or 60Hz (operating voltage and frequency can be selec-
ted as described in section 6 and 18 of this manual). Prior to connecting the unit to your mains supply, ensure that the model in
your possession correctly matches the mains supply available to you.
For connection purposes, ensure your plug is of a suitable rating:
at 230 V: 2 Amps on startup, 1,6 amps constant draw in normal operation
a 115 V: 4,2 Amps on startup, 3,2 amps constant draw in normal operation
Locate the mains cable which exits the base of the unit and connect as shown below:
protection
The use of a thermal magnetic circuit breaker is recommended for each
iCyc 250
.
A good earth connection is essential for the correct operation of the fixture. Strict adherence to regulatory norms is strongly recom-
mended.
iCyc 250 must be grounded; never install the unit unless the yellow/green ground cable is securely con-
nected.
massa/ground
neutro/neutral
fast/live
marrone - brown
blu - blue
giallo/verde - yellow/green
alimentazione
main
7. Mains connection
7