ENTER
ENTER
ENTER
AUTOMATIC
DIF. START
0,3 bar
TIMER STOP
5 s
VIEW MODE
PRESSURE
P LINE
SET P
0,0 bar
0,0 bar
Hz LINE SET P
FL
42 2,0 bar 2,0 1
11.The default value is 0,3 bar. This value of pressure is the one that the system
will subtract to the input pressure, resulting the final pressure to which the
system will set in motion when the hydraulic network have a demand. Using
keys
to modify the initial value. It is recommended to maintain this value
between 0,3 and 0,6 bar. Example:
- Input pressure:
2 bar.
- Differential start:
0,3 bar.
- Final start pressure:
2 - 0,3 = 1,7 bar.
The value should be greater as much as smaller be the accumulation and vice
versa.
12. “TIMER STOP” default value is 5”. This will be the employed time by the
system in stopping once ceased the consumption in all the installation. Using
keys
we can modify the initial.
13. There are 2 view modes to choose::
- Pressure: it is visualized “P LINE” (real pressure of the installation) and “SET P”
(working programmed pressure).
- Service: it is visualized “Hz” (working frequency of the inverter), “LINE” (input
pressure chosen), “SET P” (real pressure of the installation) y “FL” (flow sensor
state).
14. After pressing ENTER pushbutton, the system will remain
configured showing the type of view chosen in the previous
section.
Press AUTOMATIC in order to quit manual mode.
pq
pq
REGISTER OF FUNCTIONS AND ALARMS
Pushing simultaneously MENU +
during 3” we will get the register of functions and alarms, by mean of the
pushbutton ENTER we are able to advance inside the register, once we get the last register we can go back to the
main menu pushing ENTER again. The visualization sequence is as follows:
p
P LINE
SET P
0,0 bar
0,0
ALARM REGISTER
SHORTCIRC.
0
ALARM REGISTER
I MAX
0
ALARM REGISTER
I MAX. AUX.
0
ALARM REGISTER
NO WATER
ALARM REGISTER
TEMP.
0
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
P LINE
SET P
0,0 bar
0,0
FUNCTION REGISTER
HOURS 26 h
FUNCTION REGISTER
STARTS
32
FUNCTION REGISTER
CONNECTIONS
25
MENU+
p
Register of operational controls
Register of alarms
“CE” STAMENT OF COMPLIANCE.
COELBO CONTROL SYSTEM, S.L. We state, on our's own responsibility, thal all materials herewith related
comply with the following European standards:
2006/95/EC Low Voltage Directive on Electrical Safety
2004/108/CE Electromagnetic Compatibility.
2002/95/CE RoHS Directive
Product's name: SPEEDMATIC SET
Type: 2010 – 3010 – 2110 – 3110 – 21110 - 31110
As per the European Standards:
UNE EN 60730-1:1998+A11:1998+A2:1998+A14:1998+A15:1998+A16:1998+
A17:2001+ERRATUM A1:2001+A18:2003
UNE EN 60730-2-6:1997+A1:1998+A2:1999+CORR A1:2001+CORR A2:01
UNE EN 61000-6-2:2002
Tehnical director
F. Roldán Cazorla