3. Specifications
3.1. General
Construction
-
corrosion resistant epoxy coated aluminium housings sealed to IP66 (AQM & PSU)
-
optional 316 stainless steel and 316 stainless steel TI for heads and brackets
Electro-magnetic immunity
-
shielded to comply with 73/23/EEC - low voltage and 89/336/EEC-EMC
Ambient temperature
-
-20
o
C to +50
o
C
3.2.Power Supply Unit (PSU)
(Optional)
Outputs
-
24V DC fused
-
maximum current output must not exceed 5A (60W)
Power
-
90 to 264V AC, 47/63Hz, 100VA max.
Dimensions
-
230mm x 200mm x 110mm
3.3. Air Quality Monitor
Monitoring channels
-
up to 4 channels for CO, NO, NO², and visibility
Measurement path
-
3m (6m folded beam)
Measuring range (standard)
-
Visibility: 0-0.015 m
-1
-
CO: 0 - 300ppm
-
NO: 0 - 30ppm
-
NO²: 0
– 5/10ppm
-
Other ranges selectable on setup
Averaging time
-
1 to 12 minutes
Summary of Contents for Tunnel Tech 700 Series
Page 2: ...Issue A Rev 0 Date 25 04 17 Ref 100303...
Page 3: ...CODEL Issue A Rev 0 Date 25 04 17 Ref 100303...
Page 5: ...CODEL Issue A Rev 0 Date 25 04 17 Ref 100303...
Page 6: ......
Page 10: ...Technical Manual CODEL Issue A Rev 0 Date 25 04 17 Ref 100303...
Page 21: ...Technical Manual CODEL 11 Figure 7 Electrical Schematic...
Page 23: ...Technical Manual CODEL 13 Power Control Display PCB Electrochemical Cell PCB Communications...
Page 24: ...Technical Manual CODEL 14 Visibility PCB Ma Output PCB S Top mA RLY 4 5 Bottom mA RLY 1 2...
Page 37: ...Technical Manual CODEL 27 Alignment Laser Please Call CODEL mA Relay Card 803 604D...
Page 79: ......
Page 80: ......
Page 81: ...Technical Manual Page 1 CODEL...