USER MANUAL
31
5.1.4 PTZ
This menu allows to configure the PTZ (Pan-Tilt-Zoom) settings for the speed dome
cameras.
Channel
:
Channel name
Signal Type:
If your PTZ camera is connected to the RS485 port, then choose “
Analog
”,
otherwise choose “
Digital
”.
Below items need to be set for Analog PTZ only.
Protocol
:
Choose the communication protocol between the PTZ capable camera and NVR.
Baudrate
:
The speed of the information sent from the NVR to the PTZ-capable camera.
Make sure it matches the compatibility level of your PTZ-capable camera.
DataBit / StopBit
:
The information between the NVR and PTZ-capable camera is sent in
individual packages. The
DataBit
indicates the number of bits sent, while the
StopBit
indicates the end of the package and the beginning of the next (information) package. The
available parameters for
DataBit
are:
8
,
7
,
6
,
5
. the available parameters for the
StopBit
are
1
or
2
.
Parity
: For error check. See the documentation of your PTZ-capable camera, to configure
this setting.
Address
: Set the command address of the PTZ system. Please be noted that each PTZ-
capable camera needs a unique address to function properly