BBG-1300-OM (V1.0)
BBG-1300-FR PRODUCT MANUAL
2-27
Installation and Setup
Troubleshooting
In Case of Problems
Recovering Non-Responsive BBG-1300-FR (Device Reset)
If BBG-1300-FR powers up but is “stalled” in displaying only the Cobalt
opening splash screen graphic, the BBG-1300-FR may need to be reset.
(Normal power-up sequence shows the splash screen, then a soft key
illumination test sequence, and then finally showing the default device status
screen of system temperature data.). The non-responsive mode can occur in
rare cases where power-down/power-up occurs in a rapid pattern.
Note:
If the non-responsive condition occurs, only BBG-1300-FR device control and
monitoring functions are affected. BBG-1300-FR maintains power to device
user slots as long as AC power is connected to BBG-1300-FR.
Reset the BBG-1300-FR as follows:
1.
Power-down the BBG-1300-FR.
2.
Remove the front bezel as shown in Figure 2-5 on page 2-7.
3.
Power-up the BBG-1300-FR.
Note:
To access PCB buttons on next steps, if possible place the BBG-1300-FR on
its left side. This will make access and readability of the switch buttons and
their screened legends easier.
4.
Perform the reset sequence shown in Figure 2-11.
5.
Re-install the front bezel as shown in Figure 2-5. Within a minute, the
BBG-1300-FR should go thru its normal power-up self-test sequence,
ending with the unit displaying its default
Temperature
screen. The unit
is now reset and ready for use.
Figure 2-11 BBG-1300-FR Reset Sequence
1
Press and release RESET button
2
Press and hold SDMMC BOOT
button for 20 seconds. Blue COM
LED will turn off.
Electronic device or assembly is susceptible
to damage from an ESD event. Handle only
using appropriate ESD prevention practices.
3
Wait 1 minute and then re-install
front bezel onto chassis.
Front bezel will then show normal
initialize sequence (soft key
illumination and default display)
indicating device is now unlocked.