Operating Instructions
AceroDURO
CNC-STEP GmbH & Co. KG ▪ Siemensstrasse 13-15 ▪ 47608 Geldern ▪ Germany
Page 80
Support: +49 (0)2831/91021-50 15/05/2020
Fig. 34: Emergency stop button
1
Determine and remedy the fault cause.
2
Unlock the emergency stop button by turning
(Fig. 34) twice.
9 . 3 . 2
Che ck axes for perpendi cularity
Personnel:
•
Qualified personnel
Safety equipment:
•
protective clothing
•
Safety shoes
1
Check the Y-axis to the X axis on squareness, if necessary follow instructions given under
chapter 9.3.3.
2
Start reference run with zero-point approach; see separate instructions of the software.
9 . 3 . 3
Desc ription of proc ess for aligning the mac hine with
res pec t to per pendiculari ty.
Requirements: A complete structure of the portal system, including controller, PC and
software
.
Without a reference Run using the control software of the machine (X-axis) drive the Y-Bridge
against the side of your X Reference switch by manual, slow speed and stop for a short time(max. 5
mm / s). Thereby the two stepper motor drives of the X-axis are synchronized, and the Y-bridge
with the X-axis is aligned at right angles. After this procedure, retract the Y-Bridge by about 30mm
from the reference switch in X (depending on the position of the magnet holder of the X-axis) and
then initiate a reference run. The machine should be ready for operation.