Operating Instructions
AceroDURO
CNC-STEP GmbH & Co. KG ▪ Siemensstrasse 13-15 ▪ 47608 Geldern ▪ Germany
Page 78
Support: +49 (0)2831/91021-50 15/05/2020
9 . 2
D i a g n o s i s C h a r t
description of the
error
Cause
Remedy
Personnel
Machine has no
function
Emergency stop button
has been pressed
Cancel the emergency
stop
Operator
Toggle Signal is missing
See pin assignment in
software
qualified
personnel
Control cable broken
repair
Manufacturer
Stepper motor stands
Stepper motor (X, Y and
/ or Z-axis) is overloaded
Check connecting line if
required, check control,
see separate instructions
of the controller.
qualified
personnel
step loss
Stepper motor of the X-
axis (X1 and / or X2) is
overloaded
Check machine
perpendicularity
qualified
personnel
Travel speed too high
Correct the setting in
software
Operator
Y-the bridge is not at
right angle to the X
axis
Step losses, power
failure, physical
influence
Contact Manufacturer
Operator
Travel speed too high
Correct the setting in
software
Operator
Angular deviation in
the milling result
Y-the bridge is not at
right angles to the X axis
Contact Manufacturer
Operator
Travel speed too high
Correct the setting in
software
Operator
Cracking or loud noise
when driving the axes
PCI-interface/Parallel
port is defective
Stop the operation and
contact manufacturer
manufacturer
Lack of maintenance
Lubricate spindle waves
Operator
Real-time module is
blocked
On Windows, other
programs are still
Close programs in the
background of Windows
Operator