5.5 Optional/Advanced Memory Objects
*These values should only be modified during setup of the machine. Check all values before attempting to
run the machine.
Address
Symbol
Description
Access
%MW0
CONTROL_TYPE
Type of input control. 0, 1, or 2 Gets set by sending
“RESET” from respective device. Set to “3”
Manually for “Modbus / Other”.
(CMF / HMI = ”0”, Ethernet/IP = ”1”, Cam/Relay =
”2”, Modbus / Other = “3”).
READ/WRITE
%MW5
NUM_INNERSPOUTS
Total number of inner spouts.
READ/WRITE
%MW6
NUM_OUTLETS
Total number of outlets. Set this MW to match the
number of outlets on the distributor.
READ/WRITE
%MW7
DISTRIBUTOR_TYPE
Type of distributor. (Flat Back= ”1”, Full Round= ”2”,
Pendulum= ”3”, Head House= ”4”).
READ/WRITE
%MW32
MACHINE_STOP
Gets set to “1” by the system if a fault has occurred.
Gets reset by the system with “RESET”.
READ ONLY
%MW60
MOVING
Gets set to “1” by the system when machine is
moving.
READ ONLY
%MW67
HEARTBEAT
Toggles from “0” to “1” every 1 second. Can be
used with a timer to confirm the presence of the
machine on the bus.
READ ONLY
%MW101-n
H101-H1n (“n” = # of
outlets on the distributor)
Spout 1 outlet positions: Used to store the unique
position of each outlet.
READ/WRITE
Summary of Contents for Power Select
Page 31: ...Installation Operation Instructions CMF Power Select Ver 3 0 REV 6 3 30...
Page 32: ...Installation Operation Instructions CMF Power Select Ver 3 0 REV 6 3 31...
Page 33: ...Installation Operation Instructions CMF Power Select Ver 3 0 REV 6 3 32...
Page 34: ...Installation Operation Instructions CMF Power Select Ver 3 0 REV 6 3 33...
Page 35: ...Installation Operation Instructions CMF Power Select Ver 3 0 REV 6 3 34...
Page 36: ...Installation Operation Instructions CMF Power Select Ver 3 0 REV 6 3 35...
Page 37: ...Installation Operation Instructions CMF Power Select Ver 3 0 REV 6 3 36...
Page 38: ...Installation Operation Instructions CMF Power Select Ver 3 0 REV 6 3 37...
Page 39: ...Installation Operation Instructions CMF Power Select Ver 3 0 REV 6 3 38...