Heatsnk Over
temp
Overheat Pre-Alarm.
Heatsink is overheating. The temperature of the inverters
heatsink exceeded the setting in L08.02.
1. The inverter cooling fan has stopped.
2. Reduce the ambient temperature.
OH1
Heatsink
MaxTemp
Overheat Fault.
There are two situations that result in an overheat fault. The first
occurs when the measured heat sink exceeded 105°C. The second is a result of a
fault in the internal 24VDC cooling fan.
1. Ensure that the heat sink cooling fans are functioning.
2. Ensure that the heat sink is free from dirt and debris.
3. Ensure that the inverter’s ambient temperature is
within specifications.
4. Replace the 24VDC fan.
5. Replace the heat sink thermistor(s).
OH2
(Flashing)
Overheat 2
Overheat Alarm.
Signal is input by external terminal. H01.XX=39
OH3
Motor
Overheat 1
Motor Overheating 1.
Thermistor analog input detected motor overheating.
See L01.03.
1. Check the motor rated current value, E02.01.
2. Increase cycle time OH4 Motor or reduce the load.
OH4
Motor
Overheat 2
Motor Overheating 2.
Thermistor analog input detected motor overheating.
See L01.04.
OL1
Motor
Overloaded
Motor Overload Fault.
Inverter output exceeded the inverter overload level.
1. Ensure drive is programmed with proper motor full
load Amps (E02.01).
2. Reduce the load.
OL2
INV Overload
Inverter Overload Fault.
Inverter output exceeded the inverter overload level.
1. Reduce the load.
2. Extend the acceleration time.
OPE01
kVA Selection
kVA Settings Fault.
Inverter kVA setting range is incorrect.
1. Check O02.04 constant for proper kVA.
OPE02
Parameter Range Setting Error.
Parameter settings are set outside the
parameter range.
1. Press enter to view parameter.
2. Change parameter to appropriate setting.
OPE03
Terminal
Multi-Function Input Settings Fault.
Set values other than “F” and “FF”
are duplicated.
1. Check the settings for H01.01 to H01.07, vertify
that the same input is not used twice.
OPE04
Terminal
Parameters do not match.
The drive, control board, or terminal board has been
replaced, and the parameter settings between the controller board or terminal
board do not match.
1. Press ENTER to view the parameter.
2. Change parameter(s) to appropriate settings.
3. Set A01.05 = 5550.
OPE07
Analog Selection
Multi-Function Analog Input Setting Fault.
Set values other than 00 and 0F
are duplicated.
1. Check setting for H03.02 and H03.10. Verify that
the same value is not used twice.
OPE08
Terminal
Selection Parameter error.
A parameter has been changed that is not available
in the present control method.
1. Undo the last parameter change (if known).
2. Scroll through modified constants for obvious
setting error.
3. Perform a user initialize (A01.05=1110)
CAUTION: All settings will be restored to
the factory defaults.
OPE10
V/fPtm Setting
V/f Parameter Setting Error.
1. Check Parameters E01.04 to E01.11.
OPE23
Load Check
Check C05.04
≤
C05.07
≤
C05.09.
1. Load Check setting error.
OT1
Overtorque
Det 1
Overtorque Detection Level 1 Fault.
Current is higher than set value (L06.02)
for more than set time (L06.03).
1. Check for proper programming of L06.02 and
L06.03.
OT2
Overtorque
Det 2
Overtorque Detection Level 2 Fault.
Defined by L06.05. Alarm defined by L06.04. 1. Check for proper programming for L06.XX constant.
OV
DC Bus Overvolt
Overvoltage Fault.
The DC bus voltage exceeded for overvoltage level.
Detection level: 230V class-approximate 410V 460V class-approximate 820V
1. Extend the deceleration time.
2. Check for proper DBU operation.
3. Check the resistor.
4. Check the line voltage.
5. If on a load break hoist, check the gear box.
OV
(flashing)
DC Bus Overvolt
Overvoltage Fault.
Overvoltage occurs during stop. Main circuit DC voltage rises
above the detection level while the drive output is off. Detection level: 410V or
more for 230V, 820V or more for 460V.
1. Check the line voltage.
PF
Input Pha Loss
Input Phase Loss Fault.
Inverter input power supply has open phase.
1. Check the line voltage.
2. Remove power.
3. Retighten the input terminal screws.
4. Check the fuses.
RR
DynBrk Transistr
Braking Transistor Fault.
Internal Braking transistor failed.
1. Verify that the external braking resistor is
connected to the proper terminals.
2. Confirm that the proper resistor is installed.
3. Check for a short circuit across the braking resistor.
UL1
Upper Limt 1 Err
Upper Limit 1-SLOW DOWN Indicator.
Upper Limit 1-SLOW DOWN switch
status is changed.
1. May not require corrective action.
2. Check the position of the Limit Switch.
3. Check the condition of the Limit Switch.
4. Check the conditions of/for input
terminal H01.XX (U01.10)
Summary of Contents for Lodestar A
Page 31: ...31 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Page 32: ...32 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Page 33: ...33 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Page 34: ...34 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Page 35: ...35 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Page 36: ...36 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Page 37: ...37 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Page 38: ...38 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Page 39: ...39 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Page 40: ...40 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Page 41: ...41 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Page 42: ...42 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Page 43: ...43 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Page 44: ...44 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Page 45: ...45 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Page 46: ...46 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Page 95: ...95 00001996 REV AC 627NH October 2014 NOTES ...
Page 127: ...31 P N 10001609 REV AB 627NH December 2014 Notes ...