![Cloos qineo PULSE MASTER-Plus Operating Instructions Manual Download Page 19](http://html1.mh-extra.com/html/cloos/qineo-pulse-master-plus/qineo-pulse-master-plus_operating-instructions-manual_2625804019.webp)
19
2.1.4 Operating mode Spot welding/Interval
Press and hold torch button
•
Solenoid valve for shielding gas opens
•
Weld voltage is applied on wire electrode
•
Wire feed starts
•
Arc ignites, weld current flows
•
Welding process stops automatically after expiration of the defined
time.
Release torch button during the spot time
•
The welding process is immediately stopped
2.2 Configuration of characteristic curve
The QINEO welding power sources always use the existing synergic
characteristic curves. These default values can be adjusted in the secondary
parameters menu.
2 s
Torches
Keystroke
1 s
3 s
2 s
2 s
1 s
Welding time
Menu button
1
Illustration 53.
Selection menu basic (left) and secondary parameters (right)
1