LOCKING PROCEDURE
The locks are enabled only in MIG/MAG welding mode.
The procedure inhibits unit adjustments, allowing the user to modify only certain settings depending on the selected lock status.
The procedure is used to prevent accidental alteration of the unit settings and welding settings by the operator.
8.1.1
E
NABLING
If no locking status is selected (LoC = oFF) and if you wish to set up a limitation on use of the power source, display the Loc function in the
SETUP menu.
Open the Setup menu
§ 8
rC. The acronym relative to the setting to be edited is shown on display D1
oFF The value relative to the selected setting appears on display D2
E1
Select “LoC” with the encoder
E2
Use the encoder to select the required lock status
Depending on the selected Lock, certain functions will remain enabled
Tab. 3 Functions not disabled by Locks
E1
Select “ESC” with the encoder
S2
Press any button to save the setting and quit the Menu
Tab. 3 Functions not disabled by Locks
LoC User
interface
RC03
RC04 RC05 RC06
1
Selection of torch trigger procedure (button S5)
Display of main welding parameters (button S2)
Arc correction (encoder E2)
Wire insertion (button S1)
Gas test (button S3)
Arc
correction
(Potentiometer Pot2)
Arc correction (UP/DOWN
lever 2)
2
Selection of torch trigger procedure (button S5)
Display of main welding parameters (button S2)
Arc correction (encoder E2)
Synergy (encoder E1)
Wire insertion (button S1)
Gas test (button S3)
All adjustments enabled
All adjustments enabled
All adjustments enabled
All adjustments enabled
3
Selection of torch trigger procedure (button S5)
Display of main welding parameters (button S2)
JOB selection (encoder E2)
Wire insertion (button S1)
Gas test (button S3)
Scroll JOBS (UP/DOWN
lever 1)
Scroll JOBS (UP/DOWN
lever 1)
8.1.2
D
ISABLING
If a lock status is selected, you can only edit parameters permitted by the currently active lock status.
Open the Setup menu
§ 8
rC. The acronym relative to the setting to be edited is shown on display D1
oFF The value relative to the selected setting appears on display D2
E1
Select “LoC” with the encoder
E2
Select “oFF” with the encoder
E1
Select “ESC” with the encoder
S2
Press any button to save the setting and quit the Menu