![Cloos QINEO Micro 300 Operating Instructions/Spare Parts List Download Page 13](http://html.mh-extra.com/html/cloos/qineo-micro-300/qineo-micro-300_operating-instructions-spare-parts-list_2625795013.webp)
Micro 300
Cod.006.0001.1362
25/03/2013 v2.0
ENGLISH
13/32
8
SET-UP (INITIAL SET-UP OF THE WELDING POWER SOURCE)
Set the welding power source ON/OFF switch to “O” to switch the unit off.
SEL1
Set the selector to the symbol to select MIG/MAG welding mode
S2
Hold down the button
Set the welding power source ON/OFF switch to “I” to switch on the unit.
SIMULTANEOUS ACTIONS
Set uP The message appears on displays D1-D2 for a few seconds
rC.
The acronym relative to the setting to be edited is shown on display D1
oFF
The value relative to the selected setting appears on display D2
E1
Use the encoder to scroll the list of settings to edit
E2
Using the encoder, edit the value of the selected setting
E1
Select “ESC” with the encoder
S2
Press any button to save the setting and quit the Menu
Tab. 2 Setup settings
SETTING
Acronym on D1
Value on D2
NOTES
oFF
No remote controller enabled
Setting from user interface
3
Enables operation of connected remote controller RC03 (1 potentiometer)
Wiring diagram 16.2.1 page 30
JOBs can be retrieved
When a JOB is active the RC is inhibited
The JOB can only be quit from the interface panel
4
Enables operation of connected remote controller RC04 (2 potentiometers)
Wiring diagram 16.2.2 page 30
JOBs can be retrieved
When a JOB is active the RC is inhibited
The JOB can only be quit from the interface panel
5
Enables operation of connected remote controller RC05 (1 UP/DOWN)
Wiring diagram 16.2.3 page 31
JOBs can be retrieved
The JOB can be quit both from the panel and from RC
Remote Controller Selection
rC
6
Enables operation of connected remote controller RC06 (2 UP/DOWN)
Wiring diagram 16.2.4 page 31
JOBs can be retrieved
The JOB can be quit both from the panel and from RC
oFF
All adjustments are disabled.
1
All adjustments are disabled with the exceptions shown in Tab.
2
All adjustments are disabled with the exceptions shown in Tab.
Lock Status Activation
LoC
3
The Loc 3 setting becomes active only when a JOB is loaded
All adjustments are disabled with the exceptions shown in Tab. 3 page 14.
When no JOB is loaded, the user interface is completely unlocked
oFF
The setting activates the push-pull torch
Push-Pull Activation
PP
on
The setting deactivates the push-pull torch
SPc
The setting activates Special burning
Selection Of Burn Type
bb.
Std
The setting activates Standard burning
Quitting The Menu
ESC
To quit the menu select this setting and press button S1