![Cloos QINEO Micro 300 Operating Instructions/Spare Parts List Download Page 9](http://html.mh-extra.com/html/cloos/qineo-micro-300/qineo-micro-300_operating-instructions-spare-parts-list_2625795009.webp)
Micro 300
Cod.006.0001.1362
25/03/2013 v2.0
ENGLISH
9/32
5
USER INTERFACE
Code Name Symbol
Description
This LED illuminates to show an anomaly in the operating conditions.
L1 ALARM
When this LED illuminates the last voltage and current values measured during welding will be shown on displays D1-
D2.
L2 MEASURED
VALUE
The LED switches off when a new welding procedure is started, or when any of the welding settings is modified.
L3 SOCKETS
POWERED
This LED illuminates to confirm the presence of power on the output sockets.
L4 UNIT OF MEASUREMENT IN
METRES PER MINUTE
Illuminates to show that the value on display D1 is expressed in metres per minute.
L5 UNIT OF MEASUREMENT IN
AMPERES
When this LED illuminates the Amperes value is shown on display D1.
L6 UNIT OF MEASUREMENT IN mm
This LED indicates that the value shown on D1 is in mm
L7 UNIT OF MEASUREMENT IN
SECONDS
This LED indicates that the value shown on D2 is in seconds or milliseconds
L8 UNIT OF MEASUREMENT IN
VOLTS
When this LED illuminates a Voltage value is shown on display D2.
L9 UNIT OF MEASUREMENT IN %
This LED indicates that the value shown on D2 is in a percentage
L10 WIRE FEED RATE
Illuminates to show that the wire feed rate value can be set on display D1
L11 AMPERES
Illuminates to show that the welding current value in Amperes can be set on display D1
Illuminates to confirm the possibility of setting the recommended base material thickness is displayed on D1.
L12 THICKNESS
Reference is made to "T" fillet welds on identical thicknesses.
The relative value is purely guideline.
L13 PROGRAMS
Illuminates to show that the required Synergic welding program can be set
This LED illuminates to show that the torch trigger 2 times procedure is selected.
L14 TWO TIMES PROCEDURE
§. 13.1
This LED illuminates to show that the torch trigger 4 times procedure is selected.
L15 FOUR TIMES PROCEDURE
§. 13.2
This LED illuminates to show that the torch trigger 3 Level procedure is selected.
L16 THREE LEVEL PROCEDURE
The procedure can be activated in synergic programs in MIG/MAG mode.
§. 13.5