CLIVET TALK MODULAR SYSTEM COMPOSITION
CLIVET TALK system is made up of different modules connected to each other with the CAN OPEN protocol.
The system configuration varies according to the typology of the unit and of the accessories: not always the represented
electric modules are all presents on the unit.
INTERFACE
code C5110821
The interface module allows for the control of the operations of the whole
machine, the programming of the different adjustment parameters and also to
display the alarms and the unit status.
CENTRAL MODULE
code C5110694
The central module manages the system configuration, the working mode, the
set point, the thermal adjustment, remote inputs.
H
L
g
nd
J1
7
10
8
6
4
2
9
7
5
3
1
J4
1
3
5
7
9
2
4
6
8
10
CN1
CN2
11
13
15
12
14
16
J
5
1
2
3
4
5
6
7
8
9
1
0
1
1
D
R
IV
ER
A
L
C
O
VC
M
12
3
45
6
7
8
9
1
0
1
1
1
2
SCREW COMPRESSOR MODULE
code C5110801
It manages the cooling circuit (compressors, fans, valves) and relative safety
devices.
HL
gnd
J1
7
10
8
6
4
2
9
7
5
3
1
J4
1
3
5
7
9
2
4
6
8
10
CN1
CN2
11
13
15
12
14
16
J5
1
2
3
4
5
6
7
8
9
1
0
11
DRI
V
E
R
A
L
CO
V
C
M
1
2
3
456
7
8
9
1
0
1 1
1
2
COMPRESSOR MODULE - TANDEM / TRIO
code C5110804 (tandem) – C5110801 (trio)
It manages the cooling circuit (compressors, fans, valves) and relative safety
devices.
21 20 19 18 17
1 6
1 5
1 4
1 3
1 2
DRI
V
E
R
V
CM
1
2
3
4
5
6
7
8
9
10
11
12
ELECTRONIC THERMOSTATIC EXPANSION VALVE MODULE
code C5110802
This manages the electronic thermostatic valve and the relative sensors for
control of temperature/pressure.
It is installed above the compressor module
DR
IV
E
R
V
C
M
DRIVER MODULE
code C5110803
The electronic thermostatic valve management firmware is located here.
It is mounted on the expansion module.
HL
gn
d
J1
7
J1
2
CN1
CN2
DIP1
DIP2
JUMP4
STRIP
gn
d
OFF
ON
1
2
3
4
OFF
O
N
1
2
3
4
567
8
12
34
56
9
7
5
3
1
10
8
4
2
6
2
4
6
8
10
1
3
5
7
9
JUMP1
JUMP2
JUMP3
EVAPORATOR MODULE
code C5110674
It manages components, safety devices, inputs and outputs relative to the
water circuit (pumps, differential manostat, temperature probes)
HL
gn
d
J1
7
J1
2
CN1
CN2
DIP1
DIP2
JUMP4
STRIP
gn
d
O
FF
ON
1
2
3
4
O
FF
ON
1
2
3
4
567
8
1234
5
6
9
7
5
3
1
10
8
4
2
6
2
4
6
8
10
1
3
5
7
9
JUMP1
JUMP2
JUMP3
PUMP MODULE
code C5110701
It manages controls and safety devices relative to the circulation pumps
HL
gnd
8
9
10
11
JUMP4
123
4
5
67
DIP1
DIP2
STRIP
OF
F
O
N
1
2
3
4
OF
F
O
N
1
2
3
4
5
6
7
8
JUMP1
JUMP2
JUMP3
1
3
5
7
9
2
4
8
10
6
CN2
CN1
16
14
12
10
8
6
4
2
15
13
11
9
7
5
3
1
J22
J15
gnd
RECOVERY MODULE
code C5110679
It manages the electrovalves and the pumps relative to the recovery circuit.
Все каталоги и инструкции здесь:
http
:
//splitoff.ru/tehn-doc.html