31
Parameter 3: MMS password
Parameter 4: MMS server
Parameter 5: MMS proxy
Parameter 6: MMS proxy port (
1~65535
)
RSTG
Reset GSM
Send SMS Example =>
RSTG
:
UPLD
Change media
upload setting
Send SMS Example =>
UPLD
:1,http://192.168.0.190:8080/upload/up-post.php
Parameter 1: Upload destination (
1~5
)
Parameter 2: Upload destination URL
UPPF
Change media
upload prefix
Send SMS Example =>
UPPF
:1234
Parameter 1: Media upload prefix
FMUG
Panel
Firmware
Upgrade
Send SMS Example =>
FMUG
:http://192.168.0.190:8080/firmware/upgrade.bin
Parameter 1: URL to download firmware
HAED
Change home
automation
rule
Send SMS Example =>
HAED
:1,a1.mode==0, g=1&sw=off&pd=60
Parameter 1: Rule Number (
1~20
)
Parameter 2: Rule condition
Mode Change:
a
1.mode==0 : Disarm
a1.mode==1 : Away Arm
a1.mode==2 : Home Arm 1
a1.mode==3 : Home Arm 2
a1.mode==4 : Home Arm 3
Alarm:
a1.alarm==5 : Burglar
a1.alarm==6 : Smoke
a1.alarm==7 : Medical
a1.alarm==8 : Water
a1.alarm==9 : Silent Panic
a1.alarm==10 : Panic
a1.alarm==11 : Emergency
a1.alarm==13 : CO
a1.alarm==16 : High Temperature
a1.alarm==17 : Low Temperature
a1.alarm>0 : Any Alarm
Greater Temperature:
hightemp>=-1000 ~ 5000
(-10~50
℃
)
Lower Temperature:
lowtemp<-1000 ~ 5000
(-10~50
℃
)
Timer:
HHMM_hhmm_hhmm
(ex:HHMM_1230_1230)
Initial:
init
Parameter 3: Rule execution
PSS Zone Control:
a=1&z=(1~40)&sw=(on/off)&pd=(time in minutes, 0~1440, 0=always)
ex:
a=1&z=2&sw=on&pd=120
: Zone 2 on for 2 hours
PSS Group Control:
g=(1~8)&sw=(on/off)&pd=(time in minutes, 0~1440, 0=always)
ex:
g=1&sw=off&pd=60
: Group 1 off for 1 hour
Request All Media:
a=1&req=img_all;req=vid_all
Apply Scene:
a=1&trigger=USR(1~10)
ex:
a=1&trigger=USR3
: Apply Scene 3
HAAS
Apply home
automation
scene
Send SMS Example =>
HAAS
:1
Parameter 1: Scene Number (
1~10
)
Summary of Contents for VST-2752