select an attribute, Factory Default is
set to
Entry
for Door Contact and PIR
Sensor
Burglar
When the system is in any Arm
mode, if a “
Burglar
” device is
triggered, a “
Burglar Alarm
” will
be activated immediately and
reported.
Home Omit
When the system is in Home
Arm 1/2/3 mode, if a “
Home
Omit
” device is triggered, the
Control Panel will not raise
alarm. It will still send a report
for this event
When the system is in Full Arm
mode, if a “
Home Omit
” device
is triggered, the Control Panel
will respond in the same way as
if a “
Burglar
” device is triggered.
Home 1/2 Omit
When the system is in Home
Arm 1/2 mode, if a “
Home 1/2
Omit
” device is triggered, the
Control Panel will not respond. It
will still send a report for this
event
When the system is in Away
Arm or Home Arm 3 mode, if a
“
Home 1/2 Omit
” device is
triggered, the Control Panel will
respond in the same way as if a
“
Burglar
” device is triggered.
Home 1/3 Omit
When the system is in Home
Arm 1/3 mode, if a “
Home 1/3
Omit
” device is triggered, the
Control Panel will not respond. It
will still send a report for this
event
When the system is in Away
Arm or Home Arm 2 mode, if a
“
Home 1/2 Omit
” device is
triggered, the Control Panel will
respond in the same way as if a
“
Burglar
” device is triggered.
Home Access
When the system is in Home
mode, if a “
Home Access
”
device is triggered, the Control
Panel will start an Entry Delay
period to give enough time to
disarm the system. It will also
send a report for this event
When the system is in Full Arm
mode, if a “
Home Access
”
device is triggered, the Control
Panel will start a Burglar Alarm
and a burglar message will be
reported.
Delay Zone
When the system is in any Arm
mode, if a “
Delay Zone
” device
is triggered, a “
Burglar Alarm
”
will be activated immediately
and reported.
When the system is in any
Armed mode, and the Control
Panel is counting down the
Entry Delay, if a “
Burglar
”
device is triggered, the Control
Panel will not respond.
During the Exit Delay period, if a
“
Burglar
” device is triggered,
the Control Panel will not
respond .
Away Only
When the system is in Away
Arm mode, if an “
Away Only
”
device is triggered, a “
Burglar
Alarm
” will be activated
immediately and reported.
When the system is in any
Home Arm mode, if an “
Away
Only
” device is triggered, the
Control Panel will not respond.
During the Entry Delay or Exit
Delay period, if an “
Away Only
”
device is triggered, the Control
Panel will not respond .
Entry
When the system is in any Arm
mode, if an “
Entry
” device is
triggered, the Control Panel will
start an Entry Delay countdown
timer for the user to disarm the
system.
After the delay period has