18
not activated any audiable siren.
Burglar Outdoor
When the system is in Away and
Home Arm mode, if a ―
Burglar
Outdoor
‖ device is triggered,
the Control Panel will report a
―
Burglar Outdoor Alarm
‖ but
will not activated any audible
siren.
24 Hour
The
24 Hour
device is active all
the time regardless of system
mode or Entry / Exit Time. When
a
24 Hour
device is triggered,
the Control Panel will activate
and report a ―
Burglar Alarm
‖
immediately.
Fire
The
Fire
device is active all the
time regardless of system mode
or Entry / Exit Time. When a
Fire
device is triggered, the
Control Panel will activate and
report
a
―
Fire
Alarm
‖
immediately.
Medical Emergency
The
Medical
Emergency
device is active all the time
regardless of system mode or
Entry / Exit Time. When a
Medical Emergency
device is
triggered, the Control Panel will
activate and report a ―
Medical
Alarm
‖ immediately.
Water
The
Water
device is active all
the time regardless of system
mode or Entry / Exit Time. When
a
Water
device is triggered, the
Control Panel will activate and
report
a
―
Water
Alarm
‖
immediately.
Set/Unset (For Door Contact Only)
If the Door Contact is set to
Set/Unset, the system will be
disarmed
when
the
Door
Contract is triggered, and armed
when Door Contact is closed.
<NOTE>
Please refer to Normal Open/Normal
Close section below for further detail.
Silent Panic
If the device attribute is set to
Silent Panic
, when the device
is activated, the Control Panel
will report a
Slient Panic
alarm
without sounding an audible
siren.
Personal Attack
If the device attribute is set as
Personal Attack
, when the
device is activated, the Control
Panel will activate a
Panic
Alarm
report the event
Trigger Scene (Remote Controller
Only)
When a Remote Controller set
as
Trigger Scene
is activated,
the Control Panel will execute
selected Scene number accord
to Home Automation Setting.
Please refer to control apnel IP
Installation Guide for detail.
Step 5.
Select the Home Automation Scene
number which will be activated when
the device is triggered. If Disable is
selected, no Scene will be activated.
For more information, please refer to
IP Installation Guide for Home
Automation and Scene setting detail.
For Remote Controller, you must first
select “Trigger Scene” in the Remote
Controller’s Attribute selection for
scene number selection to take effect.
D i s a b l e
S c e n e 1
S c e n e 2
. . .
S c e n e 1 0
Step 6.
Select the Door Chime function (Only
available for DC, IR and PIR
Cameras). If Chime is selected, the
Control Panel will emit a ding-dong
sound when the sensor is triggered
under Disarm mode. If Off is selected,
no sound will be activated.
O f f