11
reporting threshold. If the Control Panel has
learnt in a Temperature Sensor, it will make
High Temperature report and raise alarm when
the temperature exceeds the threshold. When
the temperature drops below set value again,
the Control Panel will stop alarming and send
High Temperature Restore report. Factory
default is set to
Disable
.
Step 1.
Select
High Temp
and press
OK
to
confirm.
D i s a b l e
-
1 0
°
C
0
°
C
. . .
. . .
5 0
°
C
Step 2.
The screen will display current High
Temperature alarm setting. To change
the setting, select a new option and
press
OK
to confirm.
Low Temperature Report
This is for you to set the Low Temperature
reporting threshold. If the Control Panel has
learnt in a Temperature Sensor, it will make
Low Temperature report and raise alarm when
the temperature drops below the threshold.
When the temperature rises above set value
again, the Control Panel will stop alarming and
send Low Temperature Restore report. Factory
default is set to
Disable
.
Step 1.
Select
Low Temp
and press
OK
to
confirm.
D i s a b l e
-
1 0
°
C
0
°
C
. . .
. . .
5 0
°
C
Step 2.
The screen will display current Low
Temperature alarm setting. To change
the setting, select a new option and
press
OK
to confirm.
Bypass Fault (VST-2752 Only)
This is for you to set whether you want to
ignore fault events regarding Ethernet or GSM
function. Bypassed fault events will not
displayed or cause the fault LED will to light up
and emit beeps.
Step 1.
Select
External Tamper
and press
OK
to confirm.
D i s a b l e
I P
G S M
Step 2.
Select either disable/IP/GSM and
press
OK
to confirm.
Quick Key
This is for you to set whether to turn on/off the
Quick Key arming feature with the panel
’s
keypad. When turned on, you can arm the
control panel with a simple press of Away Arm
or Home Arm key on the keypad without
entering User PIN Code. If turned off, you can
only arm the panel by entering User Pin Code
first. For detail information about Quick Key
arming, please refer to
4.3. Away Arm Mode
and
4.4. Home Arm 1/2/3 Mode
..
Factory default is set to
On
.
Step 1.
Select
Quick Key
and press
OK
to
confirm.
O f f
O n
Step 2.
Select to turn on or off the function and
press
OK
to confirm.
Date & Time
This is for you to set your time zone, date and
time.
Step 1.
Select
Date & Time
and press
OK
to
confirm.
T i m e Z o n e
D a t e & T i m e
Step 2.
The screen will display current time
zone and date/time setting. To change
the time zone, select
Time Zone
and
press
OK
.
U T C
L o s A n g e l e s
D e n v e r
C h i c a g o
N e w Y o r k
M o n c t o n
L o n d o n
P a r i s
I s t a n b u l
M o s c o w
T a i p e i
T o k y o
S y d n e y
A u c k l a n d
A d e l a i d e
B r i s b a n e
D a r w i n
Step 3.
The screen will display current time
zone setting, To change the setting,
select a new option and press
OK
to