34
GG
= Group or Partition number (2 Hex digits 0-9, B-F). Use 00 to indicate that no
specific group or partition information applies.
<space>
=
Delimited for GG and CCC
CCC
= Zone number (Event reports) or User # (Open/Close reports) (3 Hex digits 0-9,
B-F). Use 000 to indicate that no specific zone or user information applies.
<space>
=
Delimited for CCC and SSSS
SSSS
=
Using the 8-bit Fletcher Checksum Algorithm
<NOTE>
The Checksum is calculated up to CCC (including space).
The category to which each event belongs is shown in the brackets following every
event description. The event filter will process events according to the categories to
which events are assigned.
For example, in the case of
“100 –VCP-LTE Emergency (medical)”, “medical” means the
category to which the event
“VCP-LTE Emergency” is assigned.
Event Codes:
100 - Panel emergency
When the Alarm Button of the VCP-LTE is pressed.
101 - Personal emergency
When the Wrist Transmitter / Emergency Pendant (WTR), or Fall Sensor is
pressed.
102
– Inactivity after fall detection
If no sudden movement within 10 seconds after fall detection, an inactivity code
will be sent to Central Monitoring Station.
111 - Smoke emergency
When the Smoke Detector (SD) is triggered.
114 - Heat Emergency
When Heat Detector (HD) is triggered.
When Heat alarm is restored.
120 - Panic
When the Alarm Button of the VCP-LTE
is pressed (“Help Event” set as 120).
151 - Gas Emergency
When gas alarm is triggered.
When gas alarm is restored.
154 - Water emergency
When Water Sensor (WS) is triggered.
When water alarm is restored.