background image

31 

 

at least 1 second. 

 

The  function  of  pressing  sensor  button  to  end  call  is  now  programmable  via  PC 
Programming Tool or SMS command. Default is disabled. 

 

At 20 and 10 seconds before the communication time expires, VCP-LTE will emit 1 
beep via the telephone handset to alert the user.   

 

If  the  call  recipient  needs  more  talk  time,  he  can  press  any  key  except  for  (

9

)  to 

reset the communication time to its preset duration. 

 

If  no  DTMF  command  is  pressed  during  the  speech  period,  the  call  will 
automatically  hang  up  and  be  recorded  as  an  unsuccessful  report.  Each  phone 
number will be retried up to a maximum of 5 times accordingly. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for VCP-LTE

Page 1: ...VCP LTE Voice Call Point Installation Guide Nov 19 2021...

Page 2: ...__________________________________________________________ 12 4 1 3 APN ____________________________________________________________________________ 13 4 1 4 Report ___________________________________...

Page 3: ...th the monitoring center The medical alarm system can integrate with multiple devices sensors Wrist Transmitter Emergency Pendant Fall Sensor PIR Motion Sensor Panic Button Smoke Detector Water Leakag...

Page 4: ...ry 5 seconds GSM fault 3 LED Indicator Green Light on AC Power on Flashes once every 5 seconds AC Fail 4 Speaker 5 Microphone 6 DC Jack For connecting to 9V 1A DC adaptor 7 Battery Switch 8 Micro USB...

Page 5: ...the AC power adapter is used to supply power to VCP LTE and at the same time recharge the battery It takes approximately 72 hours to fully charge the battery If the battery switch is set as OFF the ba...

Page 6: ...Card will delete its SMS messages whenever the VCP LTE is powered on WARNING Only a Nano SIM card can fit it the SIM card slot If you don t have the right SIM size please contact your service provider...

Page 7: ...mark on VCP LTE B is aligned with the upper mark on the bracket 6 Rotate VCP LTE clockwise to the lock position Surface Placement The VCP LTE can be deployed on a flat surface without being installed...

Page 8: ...VCP LTE follow the hardware installation steps below Step 1 Insert the device cradle end of the Programming Micro USB Cable into the Micro USB jack as shown in the picture Step 3 Insert the programmin...

Page 9: ...WARNING If programming cable is not provided please contact your supplier DO NOT attempt to connect VCP LTE to computer with a regular Micro USB cable Programming Micro USB Cable Regular Micro USB Cab...

Page 10: ...1 Make sure VCP LTE and the computer is connected properly please refer to 3 3 Hardware Installation Step 2 Please go to http www ftdichip com Drivers VCP htm Scroll down the webpage and select the dr...

Page 11: ...rogramming Tool software via USB port follow instruction below Step 1 Execute the programming tool The following configuration screen will be opened Step 2 Select the following settings in the top sec...

Page 12: ...None Step 3 Read Configuration To start configuring VCP LTE settings click on Open A Read configuration success message will pop up click OK to proceed The current VCP LTE setting will be displayed Cl...

Page 13: ...tion To access Current Setting again click on Read Default When Default is selected the PC Programming Tool will display default configurations of VCP LTE you can use this profile to return VCP LTE to...

Page 14: ...e or No to return to the previous page 4 1 2 SMS Program This tab allows the user to program SMS Keyword 15 characters max and Access Code 1 4 8 digits which are used for SMS Programming feature Enter...

Page 15: ...an access point for GPRS Please ask your SIM card service provider for your APN APN User Offered by your SIM card service provider Please ask your service provider for your GPRS username If no usernam...

Page 16: ...The event filter determines which events are reported to the selected Report Destination 3 Reporting Format Type Select a reporting format The reporting format determines how the events are reported...

Page 17: ...ion If two way communication is required after an IP or SMS report please program a separate Speech Report Alternatively the user can also utilize Callback operation Event Filter This parameter determ...

Page 18: ...ge containing event information Group The Reporting Group determines the sequence of reporting One Report Index can only be assigned to one Group Reporting within a Group If there are multiple Report...

Page 19: ...t Index within the group for 4 tries VCP LTE will start reporting to the next group When reporting to the second group succeeds reporting is regarded as successful If no other group is programmed VCP...

Page 20: ...Report text format Below are the SMS Text messages sent to user according to the condition of the Base SMS text table VCP LTE Condition SMS Text format Low battery status VCP Low Battery Battery volta...

Page 21: ...ds After the Guard Time has expired VCP LTE will begin report the alarm event cannot be cancelled after Guard Time has expired Guard Time Fall Sensor The Guard Time for Fall Sensor s fall detection fu...

Page 22: ...ll auto answer the call after the first ring and wait for the Access Code default 1111 and key entry within 15 seconds When the correct Access Code is received VCP LTE will open a full duplex Two way...

Page 23: ...n it will consider the device out of order and report the event accordingly Supervision Timer Repeated Set the interval that the supervision failure report will be repeated after the first Supervisory...

Page 24: ...Access Code default 1111 and key entry within 15 seconds before it opens a full duplex Two way communication If the correct Access Code and the key are not entered within 15 seconds the system will d...

Page 25: ...sers can use the Add Sensor function to include sensors into the VCP LTE Click on the Add Sensor button Enter the Sensor ID the barcode on the back of the sensor A sensor ID is a combination of digits...

Page 26: ...nal strength The IMEI number of GSM module will be displayed on the right side of GSM signal strength Reboot Device Click Reboot Device to reboot VCP LTE This will not remove any programmed parameters...

Page 27: ...ll start Total elapsed time will be displayed to show how long the updating process has elapsed Step 3 When updating process is completed a message Firmware update success will be displayed in a pop u...

Page 28: ...position of the command is completed You can send the command to VCP LTE now NOTE If the SMS message text format of your mobile phone is not English please change it to English for SMS remote programm...

Page 29: ...icate it has learned in the pendant Step 3 Repeat Step 2 3 to learn in all devices device learnt in will be assign from Zone 1 to 20 in sequence If VCP LTE has already learnt in 20 devices it will emi...

Page 30: ...Alarm Button for 5 seconds to hang up or press the learnt in RF device WTR Fall Sensor or PB button once to hang up The caller can press either DTMF 9 key or put the handset back to the base cradle to...

Page 31: ...cancelled after Guard Time Fall Sensor has expired This function is only used when a fall is detected if the Alarm Button on VCP LTE or the Active Button of the learnt in Fall Sensor is pressed to act...

Page 32: ...enable a designed shortcut function please press the DTMF key for at least 1 second The function of pressing sensor button to end call is now programmable via PC Programming Tool or SMS command Defaul...

Page 33: ...s VCP LTE will emit 1 beep via the telephone handset to alert the user If the call recipient needs more talk time he can press any key except for 9 to reset the communication time to its preset durati...

Page 34: ...gency No report destination Factory reset FTSET FTSET PROG 1111 To execute a factory reset To reboot VCP LTE RESET RESET PROG 1111 To restart VCP LTE Remote Firmware Upgrade FWUG FWUG PROG 1111 59 124...

Page 35: ...Event code 3 Hex digits 0 9 B F GG Group or Partition number 2 Hex digits 0 9 B F Use 00 to indicate that no specific group or partition information applies CCC Zone number Event reports or User Open...

Page 36: ...example in the case of 100 VCP LTE Emergency medical medical means the category to which the event VCP LTE Emergency is assigned Event Codes 100 Panel emergency When the Alarm Button of the VCP LTE i...

Page 37: ...cleared 311 Panel Battery Disconnected When the Control Panel s battery is not connected When the Control Panel s battery disconnected status is cleared 383 Device Tamper Device Tamper Restore When an...