4.1.5 Setting
The Setting tab allows you to program general configuration for VCP-LTE.
Click “Write”
when you have completed all settings to confirm.
Help Event (Selecting an event code):
You can select the event code to be sent to the CMS when the Alarm Button of
VCP-LTE
is pressed. Choose your preferred event code in the box after “Help
Event” and click “Write.”
There are three options for the event code:
- 100: Medical
- 101: Emergency
- 120: Panic
Guard Time:
The Guard Time will begin to count down when the Alarm Button of VCP-LTE
is pressed. If a false alarm is triggered, it can be canceled during guard time
by pressing and holding the Alarm Button for 5 seconds.
After the Guard Time has expired, VCP-LTE will begin report, the alarm event
cannot be cancelled after Guard Time has expired.
Guard Time Fall Sensor:
The Guard Time for Fall Sensor
’s fall detection function is set separately from
regular Guard Time.
If a false alarm is triggered by Fall Detection, it can be canceled within the
guard time fall sensor period by pressing the Alarm Button of VCP-LTE for 5
seconds or pressing the Active Button of the learnt-in RF device for a duration
determined by the device (please refer to the device user manual).
After the Guard Time Fall Sensor has expired, VCP-LTE will begin report, the
alarm event cannot be cancelled after Guard Time Fall Sensor has expired.
This function is only used when a fall is detected, if the Active Button of the
learnt-in Fall Sensor is pressed to activate alarm, normal guard time is used