30
Time.
-
1052-QT-DT35AW can be programmed to delay alarm reporting (triggered by Fall detection)
from (
00
) (instant reporting) to (
99
) seconds.
-
During this period, a continuous series of beeps will be emitted to alert user. If a false alarm is
triggered by
Fall Sensor
, it can be cancelled within the Guard Time Delay.
-
If an emergency alarm is triggered by pressing the Active Button on Fall Sensor, the guard time
delay time is determined by Command #42 Guard Time Delay, instead of Command #66
Guard Time Delay Time for Fall Sensor.
76# Call Progress Tone:
-
When turned on, you will hear a dialing tone from the speaker indicating the status of phone
calls.
-
When this function is set to OFF, you will not hear the dialing tone of phone calls.
-
This function will be disabled if Silent Mode (Command 35) is enabled, or alarm activation is
made from a Silent Device (learnt using Command #93).
77# Speech Report ACK
-
When speech report is set to (0), press any DTMF key for panel to regard speech reporting
successful.
-
When speech reporting is set to (1), off-hook phone for panel to regard speech reporting
successful.
-
Factory default is (0), Any DTMF.
4.4.1.5 Device
The Device tab allows user to learn in or remove devices from CTC-1052-QT
-
DT35AW. The
system can learn a total of 20 sensors. All learnt-in devices will be assigned to zone 1-20
sequentially.
93# Learn-In Silent Device:
-
This is used for learning in silent devices. When
CTC-1052-QT-DT35AW receives the alarm
signal from a Silent Device, it will not sound any warning beeps during Reporting and Guard
time period.
94# Learn-In Device: