11
function
is
enabled),
CTC-1052-QT-
DT35AW will auto-answer the call after the
1st-2nd ring and waits for Access Code
(default is 1111) and the (#) key entry within
15 seconds.
When the correct Access Code is received,
CTC-1052-QT-DT35AW will then open a
Full-Duplex Communication to allow the
Call Recipient to speak to CTC-1052-QT-
DT35AW directly.
You can use DTMF command to switch the
communicating method. Please refer to
section
4.2. Alarm Activation
.
<NOTE>
The Access Code must be entered
within 15 seconds. Otherwise, CTC-
1052-QT-DT35AW will disconnect the
call automatically.
To terminate the call, press DTMF (
9
),
(
0
) or
Reset Button
on 1052-QT-
DT35AW.
If the 5-minute waiting period is up,
CTC-1052-QT-DT35AW
will
automatically exit this waiting mode
and return to idle mode.
Command 40
Set Access Code
The Access Code is used to enter
Programming Menu (locally or remotely),
and the Call-Back Function.
It consists of 4 digits and has been set to
(
1111
) as factory default. Before you set
your own Access Code,
(
1111
) must be
keyed in.
To set a new Access code; enter the
desired (
4-digit number)
in
Function
Selection
.
Command 41
Auto Answer for Remote Programming
CTC-1052-QT-DT35AW
can
be
programmed to auto answer incoming
phone calls after a pre-set number of rings
have been reached. The number of rings
range from (
00
) (no auto answer) to (
32
)
rings.
Function Selection
Result
(00)
OFF
(01) - (32)
ON
Factory Default is (
00
) Rings.
<NOTE>
When (
00)
, it means CTC-1052-QT-
DT35AW cannot auto-answer the call
by ring count. If you want to do Remote
programming,
please
follow
the
Remote
Programming
method
described in
4. System Confguration,
4.1. Remote Programming Mode,
4.1.2. Dial in Twice
.
Command 42
Guard Time Delay
This command is designed for any
compatible sensor, except Fall Sensor
(fall detection).
Guard Time Delay time is a time period
programmed to delay alarm reporting. If a
false alarm is raised, it can be cancelled
within this Guard Time Delay time.
The programmable delay time range from
(
00
) (instant reporting) to (
99
) seconds.
Emergency alarms activated by Smoke
Detectors
(SD),
Carbon
Monoxide
Detectors (CO), Carbon Dioxide Detector
(CO2), Temperature Sensor (TS), and
Water Sensors (WS) do not have Guard
Time Delay and will be reported
immediately.
Function Selection
Result
(00)
INSTANT REPORTING
(01) - (99)
DELAY
Alarm activated by pressing a button
cannot be cancelled after the Guard Time is
elapsed.
<NOTE>
The Guard Time Delay time from
pressing the Active Button on a Fall
sensor is determined by Command #42
instead of Command #66.