2
S t e p
A
– A s s e m b l y o f v i b r a t i o n d a m p e r s
The drainage pan needs space between the stand and the heating pump. Start therefore
by securing the vibration dampers in the ground stand/wall attachment, where the heating
pump’s feet are to stand. Lower the bottom rod of the vibration damper into the stand and
tighten it with the help of a flat washer and a nut - do this with all the vibration dampers.
IMPORTANT! The thick vibration dampers should be fitted on the RIGHT side of the stand.
For new installation of heating pump
First remove the heating pump’s existing vibration dampers at the marking
1
and fit the new
vibration dampers by lowering the bottom rod of the vibration damper into the ground stand/
wall attachment and tightening it using a flat washer and a nut; tighten the nuts moderately.
Do the same with the vibration damper next to the marking
2
.
For retrofitted to an existing heat pump
4
3
2
1
Do the same on vibration dampers
3
and
4
, but do not tighten the
nuts on the top before the pan is in
place under the drainage pump.
Thick