ClimAir Multi Therm-C Operating Instructions Manual Download Page 6

 

Room thermostat  MTC 

 

 

 

 

 

 

 

 

 

 

 6/12

 

Program       Block 1 
Off 

 

Heating prog 
 Cont. frost 

Clock program 

 Cont. day 

Ventilation 

 

   Off  1  

2  3 

      Overtime  

 

 

 

01:15 

A time block is for example: 
Every Monday at 7.00 day temperature; and at 17.00 night temperature. 
Go through the different programmed blocks with the + and – buttons. By pressing OK you can 
change the selected block. 

 

For days there are various options: 

off 
Mo Tu We Th Fr Sa Su 
Mo Tu We Thu Fr 

Sa Su 

    Mo 

  Tu 

And further... 
When the block has been filled in correctly, press OK to save the block. 

 
Deleting programmed blocks 

When  selecting  day,  you  can  also  select  the  off  option.  In  that  case  the  settings  of  the  block  are 
deleted. 

5.5  Heating program 

Menu (M)

Settings

Heating program 

 
This thermostat can work in different ways. 
Naturally, it can work automatically on the clock, but also in other ways. 
Cont. day  The thermostat maintains the programmed day temperature; the temperature is not 

lowered. However, you can change the temperature manually.  

Cont. night The thermostat maintains the programmed night temperature; the temperature is not 

raised. However, you can change the temperature manually. 

Cont. frost  The thermostat maintains the programmed frost temperature; the temperature is not 

raised. However, you can change the temperature manually.  

Clock program  The thermostat maintains the clock program. 

You can still change the set point manually, the set 
point will return to its automated value at the 
program step of the clock. 

Change the settings with the + and – buttons and each time 
confirm with OK. To exit the menu, press M twice. 

6

 

Ventilation 

Menu (M)

Ventilation 

 
With some devices it is possible to control the ventilator without 
the heater being on. In summer this can, for example, have a 
cooling effect. The ventilator can be switched to 4 positions: 
position 1, 2, 3 and off. Setting the ventilation. 
Change the settings with the + and – buttons and each time confirm with OK. To exit the menu, press 
M button. 

7

 

Overtime timer 

Menu (M)

Overtime program 

 
When  the  thermostat  is  set  on  the  clock  and  you  would  like 
temporarily  to  maintain  the  temperature  longer  on  day  level,  you 
can  do  so  with  the  overtime  timer. The  overtime  timer  can  be  set 
per 15 minutes. 

Enter the time, and confirm with OK. The time will start to count down immediately. 

Summary of Contents for Multi Therm-C

Page 1: ...perating instructions Clock thermostat optimising controller Operating instructions Clock thermostat MTC optimising controller Operating instructions Clock thermostat optimising controller MTC GB v03 01 ...

Page 2: ...E THERMOSTAT 7 12 DESTRATIFICATION DELAT T REGULATION 8 13 BACK TO FACTORY DEFAULT SETTINGS 8 14 REMOTE SENSOR 8 14 1 ELECTRICAL CONNECTION 8 14 2 SETTING THE CONTROLLER FOR THE REMOTE SENSOR 9 14 3 AVERAGE TEMPERATURES 9 14 4 ERRORS WITH THE REMOTE SENSOR 9 15 OPTIONAL EXTERNAL INPUT 9 16 SOLVING AND ANALYSING FAILURES 9 17 OBTAINING EXTRA INFORMATION FROM THE CONNECTED HEATERS 10 18 INSTALLER ME...

Page 3: ...different programmable time blocks Up to 8 heaters controllable Frost protection Keyboard locking Overtime program Ventilation Failure diagnosis of the devices Suppression of interference of the heater Compensation for wall influence suited for remote sensor Supplied battery excellent for preserving data in case of power failure 3 2 Technical specifications Power supply low voltage current Tempera...

Page 4: ...tat is used to reset a heater the effect must be visible In all cases the communication between the heater and the thermostat is based on a two wire low voltage connection In the thermostat has to be connected to connection 4 and 5 see also electrical wiring diagram Connect the thermostat wires to the connector If the right connector is used the thermostat will ble 1x2x0 8 shielded and twisted If ...

Page 5: ...Exit the menu by pressing M twice 5 2 Time date Menu M Settings Time Date Set the time and select whether you want to use the Daylight saving time DST To exit the menu press M twice 5 3 Temperatures Menu M Settings Temperatures During the clock program the thermostat works with 3 temperature levels in a room Day Night and Frost temperature These levels can each be set from 0 to 30 degrees Celsius ...

Page 6: ...mperature the temperature is not raised However you can change the temperature manually Cont frost The thermostat maintains the programmed frost temperature the temperature is not raised However you can change the temperature manually Clock program The thermostat maintains the clock program You can still change the set point manually the set point will return to its automated value at the program ...

Page 7: ...um time that the heaters will start earlier is 3 hours and the earlier start is not overnight 9 Keyboard locking Menu M Settings Keyboard locking Set key lock code o Default 0 0 0 0 On Off On excl overtime It may be handy to secure the thermostat in whole or in part against unauthorised changing of the settings There are several levels of security Unlocked Fully locked Limited with only the overti...

Page 8: ...ification or delta T regulation The thermostat measures the temperature on ground level and reads the temperature above in the room from the sensors on the heater When the temperature difference between the ceiling and ground level the ventilator inside the heaters will start to push the warm air down factory When this regulation is active the heater wil also stop to burn until this temperature is...

Page 9: ...543 Remote sensor Exit the menu by pressing the M button 2 times The controller can also calculate the average between its internal sensor and the remote sensor Selecte the option Average for that Errors with the remote sensor In the case that te controller sees an error regarding the remote sensor it will show an error on the display When there is no sensor found it will show error 3 When the sen...

Page 10: ...e information about the selected heater will appear The information will be shown in the English language To exit the information menu press the M button When no heater is found the display will show Heater N C not connected Screen 1 Shows the heater type Screen 2 line 1 shows the discription of the connected heater line 2 shows the status of the heater line 3 and 4 shows the temperatures from the...

Page 11: ... down 8 C value for swiching OFF Delta T2Hystereses Not used o Hyst up 4 C o Hyst down 2 C Hystereses computing value for thermostat o 0 3 C I Factor computing value for thermostat o I 5min Delta T2 regeling not used o ON OFF External sensor o ON OFF average View mode Only o ON OFF With this option the heat demand from the thermostat is disabeled The thermostat can be uses as a remote status reade...

Page 12: ...d push it into the opening on the bottom of the thermostat Carefully prise the print plate out of the top of the thermostat using a flat screwdriver See picture Carefully prise the print plate out of the holder see picture Then prise the battery out of the holder and Note Do not dispose the battery in Maintenance and service Under normal use the thermostat requires no maintenance In a very dusty e...

Reviews: