ClimAir Multi Therm-C Operating Instructions Manual Download Page 2

 

Room thermostat  MTC 

 

 

 

 

 

 

 

 

 

 

 2/12

 

1

 

Table of contents 

OPERATING INSTRUCTIONS

 

1

 

C

LOCK THERMOSTAT

  1

 

1

 

TABLE OF CONTENTS  2

 

2

 

DESIGNATED USE 

2

 

2.1

 

S

AFETY

 

3

 

3

 

DESCRIPTION OF THE THERMOSTAT

 

3

 

3.1

 

C

ONCISE SPECIFICATIONS

 

3

 

3.2

 

T

ECHNICAL SPECIFICATIONS

 3

 

4

 

MOUNTING AND ELECTRICAL CONNECTION

 

3

 

4.1

 

M

OUNTING

 

3

 

4.2

 

E

LECTRICAL CONNECTION

  4

 

4.3

 

O

NE HEATER ON ONE CONTROLLER

 

4

 

4.4

 

S

EVERAL UNITS ON 

1

 THERMOSTAT

 

4

 

5

 

SETTINGS

  5

 

5.1

 

L

ANGUAGE

 

5

 

5.2

 

T

IME

/

DATE

 

5

 

5.3

 

T

EMPERATURES

 

5

 

5.4

 

C

LOCK PROGRAM

 

5

 

5.5

 

H

EATING PROGRAM

  6

 

6

 

VENTILATION 

6

 

7

 

OVERTIME TIMER 

6

 

8

 

OPTIMISER 

7

 

9

 

KEYBOARD LOCKING

  7

 

10

 

DISPLAY

 

7

 

11

 

CALIBRATING THE THERMOSTAT

  7

 

12

 

DESTRATIFICATION (DELAT T REGULATION) 8

 

13

 

BACK TO FACTORY DEFAULT SETTINGS 

8

 

14

 

REMOTE SENSOR 

8

 

14.1

 

ELECTRICAL

 

CONNECTION: 

8

 

14.2

 

S

ETTING THE CONTROLLER FOR THE REMOTE SENSOR

 

9

 

14.3

 

A

VERAGE TEMPERATURES

 

9

 

14.4

 

E

RRORS WITH THE REMOTE SENSOR

 9

 

15

 

OPTIONAL EXTERNAL INPUT 

9

 

16

 

SOLVING AND ANALYSING FAILURES

 

9

 

17

 

OBTAINING EXTRA INFORMATION FROM THE CONNECTED HEATERS

 10

 

18

 

INSTALLER MENU

 

11

 

19

 

INTERNAL BATTERY

 

11

 

20

 

MAINTENANCE AND SERVICE

 

12

 

2

 

Designated use 

The Multi Therm-C clock thermostat has been designed to control room heaters that work according 
to the Argus bus system. This is a two-wire low voltage communication system. The thermostat is not 
suitable to switch 24V, 230V or other signals. It may only be used in dry rooms with slight impurities 
(degree of protection IP30). 

Summary of Contents for Multi Therm-C

Page 1: ...perating instructions Clock thermostat optimising controller Operating instructions Clock thermostat MTC optimising controller Operating instructions Clock thermostat optimising controller MTC GB v03 01 ...

Page 2: ...E THERMOSTAT 7 12 DESTRATIFICATION DELAT T REGULATION 8 13 BACK TO FACTORY DEFAULT SETTINGS 8 14 REMOTE SENSOR 8 14 1 ELECTRICAL CONNECTION 8 14 2 SETTING THE CONTROLLER FOR THE REMOTE SENSOR 9 14 3 AVERAGE TEMPERATURES 9 14 4 ERRORS WITH THE REMOTE SENSOR 9 15 OPTIONAL EXTERNAL INPUT 9 16 SOLVING AND ANALYSING FAILURES 9 17 OBTAINING EXTRA INFORMATION FROM THE CONNECTED HEATERS 10 18 INSTALLER ME...

Page 3: ...different programmable time blocks Up to 8 heaters controllable Frost protection Keyboard locking Overtime program Ventilation Failure diagnosis of the devices Suppression of interference of the heater Compensation for wall influence suited for remote sensor Supplied battery excellent for preserving data in case of power failure 3 2 Technical specifications Power supply low voltage current Tempera...

Page 4: ...tat is used to reset a heater the effect must be visible In all cases the communication between the heater and the thermostat is based on a two wire low voltage connection In the thermostat has to be connected to connection 4 and 5 see also electrical wiring diagram Connect the thermostat wires to the connector If the right connector is used the thermostat will ble 1x2x0 8 shielded and twisted If ...

Page 5: ...Exit the menu by pressing M twice 5 2 Time date Menu M Settings Time Date Set the time and select whether you want to use the Daylight saving time DST To exit the menu press M twice 5 3 Temperatures Menu M Settings Temperatures During the clock program the thermostat works with 3 temperature levels in a room Day Night and Frost temperature These levels can each be set from 0 to 30 degrees Celsius ...

Page 6: ...mperature the temperature is not raised However you can change the temperature manually Cont frost The thermostat maintains the programmed frost temperature the temperature is not raised However you can change the temperature manually Clock program The thermostat maintains the clock program You can still change the set point manually the set point will return to its automated value at the program ...

Page 7: ...um time that the heaters will start earlier is 3 hours and the earlier start is not overnight 9 Keyboard locking Menu M Settings Keyboard locking Set key lock code o Default 0 0 0 0 On Off On excl overtime It may be handy to secure the thermostat in whole or in part against unauthorised changing of the settings There are several levels of security Unlocked Fully locked Limited with only the overti...

Page 8: ...ification or delta T regulation The thermostat measures the temperature on ground level and reads the temperature above in the room from the sensors on the heater When the temperature difference between the ceiling and ground level the ventilator inside the heaters will start to push the warm air down factory When this regulation is active the heater wil also stop to burn until this temperature is...

Page 9: ...543 Remote sensor Exit the menu by pressing the M button 2 times The controller can also calculate the average between its internal sensor and the remote sensor Selecte the option Average for that Errors with the remote sensor In the case that te controller sees an error regarding the remote sensor it will show an error on the display When there is no sensor found it will show error 3 When the sen...

Page 10: ...e information about the selected heater will appear The information will be shown in the English language To exit the information menu press the M button When no heater is found the display will show Heater N C not connected Screen 1 Shows the heater type Screen 2 line 1 shows the discription of the connected heater line 2 shows the status of the heater line 3 and 4 shows the temperatures from the...

Page 11: ... down 8 C value for swiching OFF Delta T2Hystereses Not used o Hyst up 4 C o Hyst down 2 C Hystereses computing value for thermostat o 0 3 C I Factor computing value for thermostat o I 5min Delta T2 regeling not used o ON OFF External sensor o ON OFF average View mode Only o ON OFF With this option the heat demand from the thermostat is disabeled The thermostat can be uses as a remote status reade...

Page 12: ...d push it into the opening on the bottom of the thermostat Carefully prise the print plate out of the top of the thermostat using a flat screwdriver See picture Carefully prise the print plate out of the holder see picture Then prise the battery out of the holder and Note Do not dispose the battery in Maintenance and service Under normal use the thermostat requires no maintenance In a very dusty e...