WWW.CLF-LIGHTING.COM
7
physical installation
Warning! The machine must be either fastened to a flat surface such as a stage or wall, or clamped to a truss or
similar structure in any orientation using a rigging clamp.
Warning! At all times machine can cause injury or damage it if falls, attach an approved safety cable to one of the
safety cable attachment points on the base (see “machine overview” on page 4).
Check that all surfaces more far aways then a minimum of 200 mm. from the machine, that combustible materials
(wood, fabric, paper, etc.) are minimum 100 mm. from the nozzle, that there is free airflow around the machine
and that there are no flammable materials nearby.
Fastening the machine to a flat surface
The machine can be fastened to a fixed flat surface that is oriented at any angle. Check that the surface
can support at least 10 times the weight of all machines and equipment to be installed on it.
Warning! The supporting surface must be flat otherwise the air vents in the base may be blocked, which will cause
overheating. Fasten the machine securely. Do not place it on a surface or leave it where it can be moved or can fall
over. Attach a securely anchored safety cable to the safety cable attachment point (see “machine overview” on page.
If the machine is installed in any location where it may fall and cause injury or damage if the primary attachment
fails:
1.
Block access under the work area. Working from a stable platform.
2.
Secure the machine with a secondary attachment such as an approved safety cable that is rated for the
weight of the machine using one of the attachment points at the edges of the base (see “machine overview”
on page 4). Do not use any other part of the machine as a safety cable attachment point.
operating instructions
1.
After checking that all the parts are intact and complete, position the machine on a flat surface.
2.
Only use designated CLF Lighting smoke liquid. Machine can be harmed when using other fluids and warranty is expired.
3.
Connecting the power cord. Before power on, make sure it is connected with the rated voltage.
4.
Turn on the machine, it will immediately start heating up, the digital display will show “WARMING UP”.
Menu instruction
1.
MENU button: When it shows “HEAT”, press “menu” button to enter the page “ADDR”
2.
UP button: Increase the relevant value of each page
3.
DOWN button: Decrease the relevant value of each pag
4.
ENTER button: Enter or exit each page
Wireless Controll
When the unit is powered on, and the wireless status is ON, the LCD display will show “wireless setup”. In such case, user can register
the wireless remote by pressing any button for 1s on the remote. If the LCD display flickers twice, then it is matched with the unit suc
-
cessfully. One unit can match with 5 remotes at most. If user register the sixth one, then the memory for the first five remotes will be
erased. Press ON button to run the unit or OFF button to stop it. When the machine is under wireless remote control, the haze output
is the one set by VOLUME OUT. For example, if the VOLUME OUT is 1%, then it will be 1% when controlled by wireless remote.
Press button A to run, release it to stop. The operation of B,C,D is same as button A.
Note:
1.
When matching the wireless remote, please make sure the LCD display flicker twice. Then release the A button to match the
wireless remote, Otherwise, it might fail.
2.
If the wireless remote setup is OFF(i.e. LCD displays “Wireless Set OFF”), when the machine is powered on again, the LCD
display will not show “wireless setup”.
3.
Wireless remote control will void if the unit is connected to DMX.