physical installation

Warning! The machine must be either fastened to a flat surface such as a stage or wall, or clamped to a truss or 

similar structure in any orientation using a rigging clamp.

Warning! At all times machine can cause injury or damage it if falls, attach an approved safety cable to one of the

safety cable attachment points on the base (see “machine overview” on page 4).

Check that all surfaces more far aways then a minimum of 200 mm. from the machine, that combustible materials 

(wood, fabric, paper, etc.) are minimum 100 mm. from the nozzle, that there is free airflow around the machine 

and that there are no flammable materials nearby. 

Fastening the machine to a flat surface

The  machine  can  be  fastened  to  a  fixed  flat  surface  that  is  oriented  at  any  angle.  Check  that  the  surface 

can  support  at  least  10  times  the  weight  of  all  machines  and  equipment  to  be  installed  on  it.

Warning! The supporting surface must be flat otherwise the air vents in the base may be blocked, which will cause 

overheating. Fasten the machine securely. Do not place it on a surface or leave it where it can be moved or can fall 

over. Attach a securely anchored safety cable to the safety cable attachment point (see “machine overview” on page.

If the machine is installed in any location where it may fall and cause injury or damage if the primary attachment 

fails:

1. 

Block access under the work area. Working from a stable platform. 

2. 

Secure the machine with a secondary attachment such as an approved safety cable that is rated for the 

weight of the machine using one of the attachment points at the edges of the base (see “machine overview” 

on page 4). Do not use any other part of the machine as a safety cable attachment point.

operating instructions

1. 

After checking that all the parts are intact and complete, position the machine on a flat surface.

2. 

Only use designated CLF Lighting smoke liquid. Machine can be harmed when using other fluids and warranty is expired.

3. 

Connecting the power cord. Before power on, make sure it is connected with the rated voltage.

4. 

Turn on the machine, it will immediately start heating up, the digital display will show “WARMING UP”. 

Menu instruction

1. 

MENU button: When it shows “HEAT”, press “menu” button to enter the page “ADDR”

2. 

UP button: Increase the relevant value of each page 

3. 

DOWN button: Decrease the relevant value of each pag

4. 

ENTER button: Enter or exit each page 

Wireless Controll

When the unit is powered on, and the wireless status is ON, the LCD display will show “wireless setup”. In such case, user can register 

the wireless remote by pressing any button for 1s on the remote. If the LCD display flickers twice, then it is matched with the unit suc

-

cessfully. One unit can match with 5 remotes at most. If user register the sixth one, then the memory for the first five remotes will be 

erased. Press ON button to run the unit or OFF button to stop it. When the machine is under wireless remote control, the haze output 

is the one set by VOLUME OUT. For example, if the VOLUME OUT is 1%, then it will be 1% when controlled by wireless remote. 

Press button A to  run,  release it to stop. The operation of B,C,D is same as button A.

Note:

1. 

When matching the wireless remote, please make sure the LCD display flicker twice. Then release the A  button to  match the 

wireless remote, Otherwise, it might fail. 

2. 

If the wireless remote setup is OFF(i.e. LCD displays “Wireless Set OFF”), when the machine is powered on again, the LCD 

display will not show “wireless setup”.

3. 

Wireless remote control will void if the unit is connected to DMX.

Summary of Contents for EF SMOKE 3100

Page 1: ...manual V1 0 APRIL 2018 WWW CLF LIGHTING COM ef smoke 3100 ...

Page 2: ...LIGHTING COM 2 Machine overview 3 Safety instruction 4 AC power 6 Data link 6 Physical installation 7 Operating instructions 7 Menu navigation 8 DMX channels 9 Maintenance 10 Specifications 11 table of CONTENTS ...

Page 3: ...machine overview 1 Nozzle 2 LED 3 2 5L tank 4 Tank fixing plate 5 Fluid tube 6 LCD display 7 3 pin DMX socket 8 5 pin DMX socket 9 USB 10 Ventilation 11 Handle 12 Safety point 13 Power switch 14 PoweCON 15 Overload protection ...

Page 4: ... supplier PROTECTION FROM ELECTRIC SHOCK Disconnect the machine from AC power before removing or installing any cover or part and when not in use Always ground earth the fixture electrically Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault earth fault protection Before using the machine check that all power distribution equ...

Page 5: ...onnect any other type of device to these sockets Do not stick filters masks or other materials onto any optical component Do not modify the machine in any way not described in this manual Do not connect machine to a dimmer PROTECTION FROM INJURY Ensure that persons are not looking at the LEDs from within 3 meters when the product lights up suddenly This can happen when power is applied when the pr...

Page 6: ...r s instructions Table 1 shows standard wire color coding schemes and some possible pin identification schemes if pins are not clearly identified or if you have any doubts Wire color EU models Wire color US models Conductor Symbol Screw US Brown Black Live L Yellow or Brass Blue White Neutral N Silver Yellow green Green Ground earth Green Table 1 Wire color coding and power connections or data lin...

Page 7: ...r part of the machine as a safety cable attachment point operating instructions 1 After checking that all the parts are intact and complete position the machine on a flat surface 2 Only use designated CLF Lighting smoke liquid Machine can be harmed when using other fluids and warranty is expired 3 Connecting the power cord Before power on make sure it is connected with the rated voltage 4 Turn on ...

Page 8: ...press TIMER button to activate timer mode LCD displays as below Interval 10s Interval countdown Duration 10s Duration countdown The two pages will display circularly when each countdown finish Interval and Duration time could be set in page 2 and 3 At home page press VOLUME button to activate volume mode the machine starts to fog At Channel A page press ENTER button to LED color setting page Press...

Page 9: ...nternal inspection module check out there is no oil inside the tube but the machine is still working then the machine will get into oil free protection 20s later by shutting the pump off The digital display will keep flashing 2 How to release low fluid protection When the machine is under the protection of low fluid after refilling the fluid there are three ways to release the protection 3 Keep pr...

Page 10: ... will appear the terminal symptom of heater blocking 1 heater blocked is because used inferior fog fluid or not maintenance for a long time Have nothing to do with the quality of machine Like a car with poor quality gasoline produce poor oil circuit failure or long time no maintenance the car will inevitably appear bigger problems fig 2 Solutions to these problems Fog machine heating pipes used fo...

Page 11: ...ut 54000CUFT MIN max 10m height and max 8 sec Settings and addressing Control panel with backlit LED graphic display Protocol USITT DMX512 A Wireless Color Black Housing High strenght die casting aluminium and metal Protection rating IP20 Orientation Up and downwards when fuel tank is rotated Min distance to combustable materials 100mm from machine Min distance to iluminated surfaces 200mm from ma...

Page 12: ...WWW CLF LIGHTING COM CLFLIGHTING ef smoke 3100 ...

Reviews: