background image

WWW.CLF-LIGHTING.COM

8

menu navigation

 

 

 

MENU:  

Scroll through setting menu;

 

 

 

 

UP:  

Increase, multiplex “TIMER” button; 

 

 

 

DOWN:  

Decrease, multiplex “VOLUME” button; 

 

 

 

ENTER:   In/Out, multiplex “stop” button;

Press “ MENU ” button to switch different pages, 10 pages in total:

1. 

Ready To Fog:    

The machine is ready to work

2. 

Interval Set: 

 

To set the interval of timer mode , adjustable from 1~200s

3. 

Duration Set: 

 

To set the duration of timer mode , adjustable from 1~200s

4. 

Channel A from 0-10 

Set the color when triggered by wireless remote controller button A

5. 

Channel B from 0-10 

Set the color when triggered by wireless remote controller button B

6. 

Channel C from 0-10 

Set the color when triggered by wireless remote controller button C

7. 

Channel D from 0-10 

Set the color when triggered by wireless remote controller button D

8. 

DMX512 Address:  

The DMX address can be set up from 1 to 512

9. 

Wireless Set: 

 

To turn on/off the wireless function

10. 

Language: 

 

Select the language saved by “Enter”

When the machine is not working, press “Stop” to Exit. When the machine is working, press “Stop” to stop machine working and 

go back to home page. Press UP or DOWN to change the value in each setting page. At home page, press TIMER button to 

activate timer mode, LCD displays as below:

• 

Interval 10s: Interval countdown

• 

Duration 10s: Duration countdown

 

The two pages will display circularly when each countdown finish, “Interval” and “Duration” time could be set in page 2 and 3. At 

home page, press VOLUME button to activate volume mode, the machine starts to fog

At Channel A page, press ENTER button to LED color setting page. Press UP and DOWN to choose color. Press ENTER to save 

and exit the setting. There are total 11 LED color modes, which are “OFF”, “Co1-Co9” (9 colors) and “random color changing 

(rand)” mode. The color setting of Channel A wil be effected when press button A of the wireless controller.

1. 

When set to OFF, the LED would not light up. 

2. 

9 colors are as following:

• Co 1:  Red  

 

 

• Co 6:  Orange

• Co 2:  Green 

 

 

• Co 7:  Yellow

• Co 3:  Blue 

 

 

• Co 8:  Sky blue

• Co 4:  Pink  

 

 

• Co 9:  White

• Co 5:  Purple

After setting the color, the corresponding color will light up when output controlled by wireless remoter. When Random mode, the 

LED will change color randomly, the interval is 1s.  

 

Note:

  When connected to DMX controller, the color setting from this page will be invalid, the LED color would be controlled by 

DMX controller 

Wireless remote control button 1-4 trigger the options set in the color program CH-1-CH-4, 

 

respectively. DMX When connected DMX controller, the LCD shows DMX address setting page only, to easily set DMX address.

Summary of Contents for EF SMOKE 3100

Page 1: ...manual V1 0 APRIL 2018 WWW CLF LIGHTING COM ef smoke 3100 ...

Page 2: ...LIGHTING COM 2 Machine overview 3 Safety instruction 4 AC power 6 Data link 6 Physical installation 7 Operating instructions 7 Menu navigation 8 DMX channels 9 Maintenance 10 Specifications 11 table of CONTENTS ...

Page 3: ...machine overview 1 Nozzle 2 LED 3 2 5L tank 4 Tank fixing plate 5 Fluid tube 6 LCD display 7 3 pin DMX socket 8 5 pin DMX socket 9 USB 10 Ventilation 11 Handle 12 Safety point 13 Power switch 14 PoweCON 15 Overload protection ...

Page 4: ... supplier PROTECTION FROM ELECTRIC SHOCK Disconnect the machine from AC power before removing or installing any cover or part and when not in use Always ground earth the fixture electrically Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault earth fault protection Before using the machine check that all power distribution equ...

Page 5: ...onnect any other type of device to these sockets Do not stick filters masks or other materials onto any optical component Do not modify the machine in any way not described in this manual Do not connect machine to a dimmer PROTECTION FROM INJURY Ensure that persons are not looking at the LEDs from within 3 meters when the product lights up suddenly This can happen when power is applied when the pr...

Page 6: ...r s instructions Table 1 shows standard wire color coding schemes and some possible pin identification schemes if pins are not clearly identified or if you have any doubts Wire color EU models Wire color US models Conductor Symbol Screw US Brown Black Live L Yellow or Brass Blue White Neutral N Silver Yellow green Green Ground earth Green Table 1 Wire color coding and power connections or data lin...

Page 7: ...r part of the machine as a safety cable attachment point operating instructions 1 After checking that all the parts are intact and complete position the machine on a flat surface 2 Only use designated CLF Lighting smoke liquid Machine can be harmed when using other fluids and warranty is expired 3 Connecting the power cord Before power on make sure it is connected with the rated voltage 4 Turn on ...

Page 8: ...press TIMER button to activate timer mode LCD displays as below Interval 10s Interval countdown Duration 10s Duration countdown The two pages will display circularly when each countdown finish Interval and Duration time could be set in page 2 and 3 At home page press VOLUME button to activate volume mode the machine starts to fog At Channel A page press ENTER button to LED color setting page Press...

Page 9: ...nternal inspection module check out there is no oil inside the tube but the machine is still working then the machine will get into oil free protection 20s later by shutting the pump off The digital display will keep flashing 2 How to release low fluid protection When the machine is under the protection of low fluid after refilling the fluid there are three ways to release the protection 3 Keep pr...

Page 10: ... will appear the terminal symptom of heater blocking 1 heater blocked is because used inferior fog fluid or not maintenance for a long time Have nothing to do with the quality of machine Like a car with poor quality gasoline produce poor oil circuit failure or long time no maintenance the car will inevitably appear bigger problems fig 2 Solutions to these problems Fog machine heating pipes used fo...

Page 11: ...ut 54000CUFT MIN max 10m height and max 8 sec Settings and addressing Control panel with backlit LED graphic display Protocol USITT DMX512 A Wireless Color Black Housing High strenght die casting aluminium and metal Protection rating IP20 Orientation Up and downwards when fuel tank is rotated Min distance to combustable materials 100mm from machine Min distance to iluminated surfaces 200mm from ma...

Page 12: ...WWW CLF LIGHTING COM CLFLIGHTING ef smoke 3100 ...