WWW.CLF-LIGHTING.COM
9
fluid
dmx channels
Channel
Function
Value
Percentage
Remark
CH 1
FOG output
010 - 255
0 - 100%
000 - 009 = OFF
CH 2
Inner LED red output
010 - 255
0 - 100%
000 - 009 = OFF
CH 3
Inner LED green output
010 - 255
0 - 100%
000 - 009 = OFF
CH 4
Inner LED green output
010 - 255
0 - 100%
000 - 009 = OFF
CH 5
Outer LED red output
010 - 255
0 - 100%
000 - 009 = OFF
CH 6
Outer LED green output
010 - 255
0 - 100%
000 - 009 = OFF
CH 7
Outer LED blue output
010 - 255
0 - 100%
000 - 009 = OFF
CH 8
Color Macro
010 - 255
0 - 100%
000 - 009 = OFF
CH 9
Color Macro speed
010 - 255
0 - 100%
000 - 009 = OFF
CH 10
LED strobe
010 - 255
0 - 100%
000 - 009 = OFF
CH 11
LED dimmer
010 - 255
0 - 100%
000 - 009 = OFF
This machine use electronic program to detect whether there is fluid inside tube or not, hence to protect the pump from being damaged
when there is no fluid.
1.
How to activate “low-fluid protection”. When the and activate it, so when the internal inspection module check out there is no oil
inside the tube but the machine is still working, then the machine will get into oil free protection 20s later by shutting the pump off.
The digital display will keep flashing.
2.
How to release “low-fluid protection”. When the machine is under the protection of low fluid, after refilling the fluid, there are three
ways to release the protection.
3.
Keep pressing the one board red fog button until the fog liquid fill the tube completely, then the machine would exit low-fluid
protection.
4.
Under the wireless remote control, keep pressing any buttons until the fog liquid fill the tube
completely, then the machine would exit low-fluid protection.
5.
Under the DMX control, firstly push the slider of channel one to the value below 10(Fog OFF),then push the slider up to value
above 10(Fog ON), the machine would exit low-fluid protection by doing so.
Note:
When the machine is heating up. HEAT page is prior to ADDR and all the other pages. Without connecting with DMX, the digital
display will back to page ADDR automatically.