Oil injection trouble: 

Refers to the fog fluid atomizing in the heater pipe of the machine is not good, heater temperature cannot be timely and effective transmit 

to the fog fluid, fog fluid cannot  all atomization and lead to oil injection.

1. 

Using the low quality or counterfeit fog fluid, low quality fog fluid have more impurities, easy to adhere to the pipe wall and hindered 

temperature transmission result in incomplete atomization caused oil injection.

2. 

Using an incorrect fog fluid. Different fog fluid have different required atomization temperature. If you use the wrong fog fluid result in 

oil cannot fully atomization caused oil injection.(fig 1)

Heater blocking trouble:

Poor atomization oil injection is the early signs of heater block.   Using poor quality fog fluid or not timely maintenance cleaning the fog 

machine for a long time. Inevitable will appear the terminal symptom of heater blocking.

1. 

heater blocked is because used inferior fog fluid or not maintenance for a long time. Have nothing to do with the quality of machine. 

Like a car with poor quality gasoline produce poor oil circuit failure or long-time no maintenance the car will inevitably appear bigger 

problems. (fig 2)

Solutions to these problems:

Fog machine heating pipes used for a long time and then the pipe wall will easily produce sediments (The more inferior fog fluid the more 

impurities thus lead to oil injection or blocked). All fog machines need regular maintenance (fog machine maintenance cycle for 1 to 2 

months/time). 

 

Specific maintenance method: after heating the 35% white vinegar plus 65%  distilled water and then spray 10 to 15 times.

Conclusion: 

As long as the fog machine with oil injection or heater blocking after using a period of time.  It was caused by fog fluid quality or lack of 

maintenance,  has nothing to do with the quality of the machine. Please use the original high quality fog fluid and timely maintain it, then it 

can be used for a long time

Summary of Contents for EF SMOKE 3100

Page 1: ...manual V1 0 APRIL 2018 WWW CLF LIGHTING COM ef smoke 3100 ...

Page 2: ...LIGHTING COM 2 Machine overview 3 Safety instruction 4 AC power 6 Data link 6 Physical installation 7 Operating instructions 7 Menu navigation 8 DMX channels 9 Maintenance 10 Specifications 11 table of CONTENTS ...

Page 3: ...machine overview 1 Nozzle 2 LED 3 2 5L tank 4 Tank fixing plate 5 Fluid tube 6 LCD display 7 3 pin DMX socket 8 5 pin DMX socket 9 USB 10 Ventilation 11 Handle 12 Safety point 13 Power switch 14 PoweCON 15 Overload protection ...

Page 4: ... supplier PROTECTION FROM ELECTRIC SHOCK Disconnect the machine from AC power before removing or installing any cover or part and when not in use Always ground earth the fixture electrically Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault earth fault protection Before using the machine check that all power distribution equ...

Page 5: ...onnect any other type of device to these sockets Do not stick filters masks or other materials onto any optical component Do not modify the machine in any way not described in this manual Do not connect machine to a dimmer PROTECTION FROM INJURY Ensure that persons are not looking at the LEDs from within 3 meters when the product lights up suddenly This can happen when power is applied when the pr...

Page 6: ...r s instructions Table 1 shows standard wire color coding schemes and some possible pin identification schemes if pins are not clearly identified or if you have any doubts Wire color EU models Wire color US models Conductor Symbol Screw US Brown Black Live L Yellow or Brass Blue White Neutral N Silver Yellow green Green Ground earth Green Table 1 Wire color coding and power connections or data lin...

Page 7: ...r part of the machine as a safety cable attachment point operating instructions 1 After checking that all the parts are intact and complete position the machine on a flat surface 2 Only use designated CLF Lighting smoke liquid Machine can be harmed when using other fluids and warranty is expired 3 Connecting the power cord Before power on make sure it is connected with the rated voltage 4 Turn on ...

Page 8: ...press TIMER button to activate timer mode LCD displays as below Interval 10s Interval countdown Duration 10s Duration countdown The two pages will display circularly when each countdown finish Interval and Duration time could be set in page 2 and 3 At home page press VOLUME button to activate volume mode the machine starts to fog At Channel A page press ENTER button to LED color setting page Press...

Page 9: ...nternal inspection module check out there is no oil inside the tube but the machine is still working then the machine will get into oil free protection 20s later by shutting the pump off The digital display will keep flashing 2 How to release low fluid protection When the machine is under the protection of low fluid after refilling the fluid there are three ways to release the protection 3 Keep pr...

Page 10: ... will appear the terminal symptom of heater blocking 1 heater blocked is because used inferior fog fluid or not maintenance for a long time Have nothing to do with the quality of machine Like a car with poor quality gasoline produce poor oil circuit failure or long time no maintenance the car will inevitably appear bigger problems fig 2 Solutions to these problems Fog machine heating pipes used fo...

Page 11: ...ut 54000CUFT MIN max 10m height and max 8 sec Settings and addressing Control panel with backlit LED graphic display Protocol USITT DMX512 A Wireless Color Black Housing High strenght die casting aluminium and metal Protection rating IP20 Orientation Up and downwards when fuel tank is rotated Min distance to combustable materials 100mm from machine Min distance to iluminated surfaces 200mm from ma...

Page 12: ...WWW CLF LIGHTING COM CLFLIGHTING ef smoke 3100 ...

Reviews: