background image

20 

 

communications equipment and the CLETEF-786 Infrared Thermometer. 
The CLETEF-786 Infrared Thermometer is intended for use in an 
electromagnetic environment in which radiated RF disturbances are 
controlled. The customer or the user of the CLETEF-786 Infrared 
Thermometer can help prevent electromagnetic interference by maintaining a 
minimum distance between portable and mobile RF communications 
equipment (transmitters) and the CLETEF-786 Infrared Thermometer as 
recommended below, according to the maximum output power of the 
communications equipment. 
Rated 
maximum 
output 
power 
of 
transmitter 

Separation distance according to frequency of transmitter m 
150 kHz to 80 
MHz 

 

80 MHz to 800 
MHz 

 

800 MHz to 2,5 
GHz 

 

0.01 

0.12 

0.23 

0.1 

0.38 

0.73 

1.2 

2.3 

10 

3.8 

7.3 

100 

12 

23 

For transmitters rated at a maximum output power not listed above, the 
recommended separation distance d in meters (m) can be estimated using 
the equation applicable to the frequency of the transmitter, where P is the 
maximum output power rating of the transmitter in watts (W) according to the 
transmitter manufacturer. 
 
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher 
frequency range applies. 
NOTE 2 These guidelines may not apply in all situations. Electromagnetic 
propagation is affected by absorption and reflection from structures, objects 
and people. 

 

 

 

1.

 The Advantages of Clever Choice Duo

TM

 

Dual mode (forehead temperature and ear temperature) 
Thanks to dual mode design, you are free to take body temperature 
by detecting the infrared heat given off by the forehead or eardrum, 
The forehead temperature measurement range is from 89.6

 to 

108.0

32

 to 42.2

.The ear temperature measurement range 

is from 32.0

 to 212.0

0

 to 100.0

The product consists of ABS plastics, temperature sensor, Infrared 
temperature measuring element, microcomputer controlled circuit, 
LCD , backlight and buzzer. 
 

Convenient for use 

 

Special ergonomic design to facilitate operation. 

 

No inconvenience would be caused to your daily life. It’s available 
for measurement when your children’s sleeping. 

 

It provides comfortable user experience compared with anus 
thermometer for children, rapid reading and simple operation 
compared with mouth thermometer. 

 

Memory recall 

A maximum of 20 previous readings is available to help you track the 
changes of your body temperature. 

 

Safe and hygienic 

 

Compared to mercury thermometer, there is no danger of 
breaking the glass or swallowing mercury. 

 

It is completely safe for children to use. 

 

Fever warning 

 

After a reading, the backlight will appear green, orange, or red to 
indicate presence and severity of a fever. When the temperature 
is more than or equal to 38.0°C/100.4 , there will be 6 short 
double and half beeps and the reading will flicker with orange 
backlight for 5 seconds. This indicates that you may have a fever. 
Please consult your doctor if you are not sure. If fever is worse, 
the backlight will appear red. 

 

Extensive clinical data of hospital 

The cooperation with designated hospitals is subjected to precise 
clinical verification, with the support of extensive clinical data and 
professional medical experts. 

Summary of Contents for CLETEF-786

Page 1: ...CLETEF 786 Infrared Thermometer Instruction Manual 0482...

Page 2: ...n be used to read body temperature by measuring the ear or forehead temperature and is suitable for both adult and children NOTE temperature of children below 3 months cannot be accurately measured wi...

Page 3: ...cklight Information 7 7 Display and Operation Instructions 8 8 Cleaning and Disinfection 11 9 Maintenance 11 10 Replacing the Batteries 12 11 Troubleshooting 12 12 Technical Specifications 14 13 After...

Page 4: ...Simple Diagnostics Inc Address P O Box 128 Williston Park NY 11596 USA Tel USA 877 342 2385 Tel Inter 1 954 603 0572 Website www SimpleDiagnostics com Email Sales SimpleDiagnostics com...

Page 5: ...ode design you are free to take body temperature by detecting the infrared heat given off by the forehead or eardrum The forehead temperature measurement range is from 89 6 to 108 0 32 to 42 2 The ear...

Page 6: ...ration distance in meters m b Field strengths from fixed RF transmitters as determined by an Electromagnetic site survey a should be less than the compliance level in each frequency range b Interferen...

Page 7: ...ipment should be used no closer to any part of the CLETEF 786 Infrared Thermometer including cables than the recommended separation distance calculated from the equation applicable to the frequency of...

Page 8: ...s test Compliance Electromagnetic environment guidance RF emissions CISPR 11 Group 1 The CLETEF 786 Infrared Thermometer uses RF energy only for its internal function Therefore its RF emissions are ve...

Page 9: ...n provided for in the 5 4 How to Use Forehead Mode Rapid measurement 1 As shown in Figure A put the cover on the probe and position the thermometer at the center of the forehead just above the eyebrow...

Page 10: ...used within 10 1 seconds Outer dimensions mm 146 5 40 52 4 Weight g Thermometer with batteries 85 0 g Liquid Ingress Protection IPX0 The date of production See the label Life 5 years The infrared the...

Page 11: ...ion No Range Sounds Backligh t Meaning Ear temperature mode 1 0 37 4 32 0 99 4 a long beep Green Acceptable 2 37 5 37 9 99 5 100 3 a long beep Yellow Elevated 3 38 0 100 0 100 4 212 0 6 short double a...

Page 12: ...xceeds 108 0 F 42 2 C in forehead temperature mode 3 short beeps with red backlight for 3 seconds The measured value falls below 32 0 F 0 C in ear temperature mode The measured value falls below 89 6...

Page 13: ...er is faulty If the warranty period has not expired contact us Only the battery symbol is displayed The battery level is low Replace the Batteries AAAx2 Er1 is displayed The ambient temperature is out...

Page 14: ...erference contains sensitive electronic 11 components and should not be used in the presence of large electromagnetic interference such as near mobile phones and microwaves Please dispose of the produ...

Reviews: