B. Operating Test for Dial Timer Control
Note: Temperatures need to be
adjusted for high altitude use (above
3500 feet). Contact Cleveland
Range at 216-481-4900 about parts
and adjustments required.
Note: Make sure the
KleanShield
, Fan Guard, and
drain pan are installed prior to
testing.
1. Turn ON the Main External Power Switch.
2. Turn ON the ON/OFF switch.
•
The control panel energizes, the Green “ADD
WATER” indicator light turns ON, and the buzzer
sounds continuously.
•
Add 3 quarts of fresh water to the reservoir. (Do
NOT use distilled water.) The Add Water buzzer will
turn OFF.
•
Add an additional 2 1/4 gallons of fresh water to
the reservoir. (Do NOT use distilled water.) The
Green “ADD WATER” indicator light will turn OFF.
•
The “ADD WATER” alarm and indicator will turn ON whenever the water level drops below
the water sensors located at the lower right front of the steamers interior. (See Figure 4-1.)
3. Set the controls:
•
Main power switch: ON.
•
ON/OFF switch: ON (The red indicator on the switch is lit).
•
TIMED/MANUAL switch: TIMED.
•
Timer: 0. (If the Timer is not zeroed, turn the dial counterclockwise to the 0 mark.)
•
Door: Open
4. Set the TIMED/MANUAL switch to MANUAL.
•
Nothing will happen as long as the door is open.
5. Close the steamer door, the steaming cycle starts.
6. Check the following functions.
•
The door interlock switch makes contact.
•
The heating elements are energized.
•
The water in the steam generator reservoir boils in a few minutes.
•
Steam is visible intermittently coming from the steam vent (the small pipe extension at the
right rear on the steamer’s back).
•
The cooking compartment reaches cooking temperature, and the heating elements cycle on
and off as the thermostat maintains cooking temperature.
•
In Manual mode, the appliance will cook continuously until turned off, or set to the Timed
mode.
•
After several minutes of steaming, check for steam leaks around the door gasket.
7. Set the timer to 0 and the TIMED/MANUAL switch to TIMED.
•
The steam generating cycle stops.
ADD WATER
PROBE
HEAT PROBE
GROUND
PROBE
Figure 4-1
Water Level Probes