9
K. High Limit Reset
•
This steamer has a high limit lockout to protect the unit from overheating.
•
If the high limit lockout temperature is reached:
1. The Red RESET light will turn ON
2. A buzzer will sound continuously
3. The heater will shut OFF
4. The steamer must be reset before cooking can continue
•
To reset the high limit:
1. Turn OFF power to the steamer with the ON/OFF switch.
2. Wait 15 minutes for the steamer to cool
3. Make sure the water probes are clean and the water level is high enough (Chapters 3 and 5).
4. Refill with water and restart according to the Power ON instructions (Chapter 3).
5. If the problem repeats, see the Operators Troubleshooting Guide (Chapter 7).
L. Water Refill
•
During operation, water level will slowly decrease.
•
Once water level falls below the center probe, the Green “ADD WATER” indicator light will come
on to let the user know to fill the reservoir.
•
During this time, the Connectionless Chef will continue to cook until the water level reaches below
the left probe. (Heat Probe)
•
Once the water level is below the left probe (Heat Probe), a buzzer will sound and the
Connectionless Chef will no longer cook until the reservoir is refilled with water. (Requires
minimum of 2 gallons)
•
To refill the compartment, pour fresh cold potable water into the slot shown in Figure 3-12.
Figure 3-12
Water Refill Location
Figure 3-11
Water Level Probes
HEAT PROBE
GROUND
PROBE
ADD WATER
PROBE
WATER
ADDED
HERE