RE-INSTALLING SPEED
CONTROL CABLE
Speed Control Assembly
1.
Turn sprocket of speed control so that wire."
A
"
is fully extended towards shaft "
B
".
2.
Insert end of cable through bracket "
C
".
3.
Insert wire so it protrudes approximately 1/2"
to 5/8" through hole in bolt "
D
". Tighten bolt
and bend end of wire.
4.
Bring pump arm "
E
" up until it hits stop bolt
"
F
" and tighten screw "
C
".
5.
Reassemble unit. Speed control knob will go
on pointing toward minimum setting.
6.
Turn mixer on with speed control set at
minimum setting.
7.
If scraper arm is turning, loosen nut "
G
" and
back stop bolt "
F
" off a few turns. Next loosen
screw "
C
" and slowly pull up cable until
scraper arm stops turning. Retighten screw
"
C
". Gently turn stop bolt "
F
" down until it hits
arm. Lock in place by tightening nut "
G
".
8.
Scraper arm should now go from no rotation
to fast rotation by turning speed control knob.
NOTE:
Mixer may run rough and noisy for one or
two hours if air has become trapped in the line.
HYDRAULIC OIL
REPLACEMENT PROCEDURE
One of the most important maintenance tasks is to
change the hydraulic oil yearly. Under heavy
usage the oil should be changed every nine
months. It is important to change the oil regularly
to prevent its breakdown which leads to the
damaging of components.
The oil filter should be changed at the same time
as the hydraulic oil. A clean filter prevents
particles from damaging the other components in
the system.
Replace the hydraulic fluid as follows:
⇒
Disconnect power to unit.
⇒
Remover the front top panel on the main
console.
⇒
Remove chrome vent cap from breather pipe
located beside electric motor.
⇒
Remove plug bolt from bottom left front corner
of main console to drain oil into your catch
pail.
⇒
Remove oil filter.
⇒
Replace plug bolt.
⇒
Refill unit through breather pipe using
approximately 12 U.S. gallons of Tellus 32
hydraulic oil (oil should be 6 1/2" deep in
tank).
⇒
Install new oil filter (Part# SE50094).
⇒
Replace chrome vent cap and front top panel.
⇒
Reconnect power to unit.
⇒
Run unit to remove any air in the lines.
NOTE:
Mixer may run rough and noisy for one or
two hours if air has become trapped in the line.
C
D
A
B
F
E
G
Summary of Contents for MKEL-100-T
Page 24: ...POWER TILT 10 CONSOLE 44 45 43...