LUBRICATION
Lubricate the following parts every three months
to insure smooth operation and reduce wear.
MIXER BRIDGE
HOUSING
There are two grease
nipples on the mixer
bridge swivel housing
which are accessed
by removing the front
and back covers on
the 18" console.
Side View of 18" Console
TRUNNION
HOUSING,
WORM SCREW
AND TILT GEAR
These parts are
accessed through the
front cover on the 18"
console.
Trunnion and Tilt Mechanism Drawing
Apply grease to gear
teeth. Check for
excessive play and
adjust with adjusting
screw located on top
of cross bar
.
KETTLE
TRUNNIONS
Accessed via the top
covers on the 10" and
18" consoles. Each
has two grease
nipples.
Kettle Trunnion Drawing
DISASSEMBLY OF SWITCH
ASSEMBLY
1.
Place slotted
screwdriver
between contactor
cartridge and
cartridge mounting
block as shown in
Fig.1
.
2.
Twist screwdriver
to free cartridge.
3.
Place screwdriver
under tab in the back
of the cartridge
mounting block as
shown in
Fig. 3
.
4.
Twist screwdriver
to remove block from
the rotary switch.
3.
Unscrew locking
ring to remove rotary
switch.
Switch Assembly
Grease
Nipples
Front
Cover
Back
Cover
Adjusting
Screw
Worm
Screw and
Tilt
Gear
Cross
Bar
Trunnion Housing
Grease Nipple
Contactor
cartridges
Cartridge
mounting
block
Locking
ring
Rotary switch
Fig. 1
Fig. 3
Fig. 2
Fig. 4
Summary of Contents for MKEL-100-T
Page 24: ...POWER TILT 10 CONSOLE 44 45 43...