OPERATING INSTRUCTIONS
Cleveland
DIGITAL WATER METER
MIN.
FAST
9
8
7
6
5
4
3
2
1
SPEED CONTROL
L
I
F
T
M
IX
ER
LIF
T
OFF
OFF
MIX LIFT
UP DOWN
MA
IN
PO
W
ER
OFF ON
EM
ERG
EN
C
Y
STO
P
MOTOR WILL NOT START
UNLESS CONTROL IS AT "MIN."
20
1
4
5
3
17
2
21
22
24
23
25
19
9
12
13
10
11
6
16
14
15
7
8
18
General Parts Drawing
(some parts shown are optional)
ITEM #
DESCRIPTION
FUNCTION
1.
Main Power Switch
Power switch for unit.
2.
Mix/Lift Switch
Sets hydraulics to mix or lift mode.
3.
Up/Down Switch
When unit is in lift mode, mixer bridge can be raised or lowered with this switch.
4.
Mixer Speed Control Dial
Controls speed of agitators and mixer bridge lift.
5.
Emergency Stop Button
Stops hydraulic system (agitators and mixer bridge lift).
6.
Mixer Bridge
Encloses agitator motors.
7.
Main Agitator Arm
Provides most of the product movement.
8.
Secondary Agitator Arm
Provides reverse agitation and product lift in kettle.
9.
Secondary Speed Control Knob
Controls speed of secondary agitator arm.
10.
On/Off Heat Switch
Controls electrical power (heat) to kettle.
11.
Heat Indicator Light (Green)
When lit, indicates that the kettle burner is on. Cycles ON-OFF with burner.
12.
Solid State Temperature
This control allows the operator to adjust the kettle temperature in increments
Control Knob
from 1 (Min.) to 10 (Max.). (see Temperature Range Chart).
13.
Low Water Indicator Light
When lit, indicates that the kettle is low on water and will not operate in this
(Red)
condition. This will also light when the kettle is tilted.
14.
Faucet Spout
Delivers water to the kettle.
15.
Hot Water Valve
Turns on hot water.
16.
Cold Water Valve
Turns on cold water.
17.
Tangent Draw-Off Valve
Used for draining product or wash water from kettle.
18.
Power Tilt Control Switch
Used for tilting the kettle up or down. Replaced by hand tilt wheel on manual tilt units.
19.
Vacuum/Pressure Gauge
Indicate steam pressure in PSI inside steam jacket as well as
vacuum in inches of mercury.
20.
Interrupt Switch
Interrupts flow without resetting water meter.
21.
Start Switch
Starts water flow to kettle.
22.
On/Off Switch
Power switch to water meter.
23.
Water Meter Control
Display and setting for water meter.
24.
Active/Bypass Switch
Switch to activate or bypass (manual operation) the controller.
25.
Temperature Controller
Digital temperature control and indicator.
Summary of Contents for MKEL-100-T
Page 24: ...POWER TILT 10 CONSOLE 44 45 43...