Operating Instructions
3. CONVOTHERM PC-Control
page
2
10 July 2006
CONVOTHERM PC-Control
3.2.1 Multi-Step Programming
1. Open the
Programming
window:
•
By double clicking on a free Program number in the Program List.
•
OR
1) Selecting a free Program number.
2) Left clicking the
Edit
dropdown menu.
3) Left clicking
Create
on the
Edit
menu.
•
OR
by right clicking the Program number.
Æ
A dropdown menu with the command
Create
opens.
2. Select an operating mode by left clicking an icon.
•
The Cook & Hold mode cannot be selected in the first step and is grey.
3. After selecting the desired operating mode, the default values appear in the entry fields
for temperature, time, and CTC (Core Probe Temperature).
•
Delta-T cooking requires the use of Core Temperature.
4. Accept the default temperature, adjust it with the arrow keys, or input the desired value
in the entry field.
5. Click the Time or CTC icon to select shutoff time or temperature.
•
Accept the default values.
•
OR
change the values with the arrow keys.
•
OR
input values in the entry fields.