Cleveland Convotherm PC-Control Operating Instructions Manual Download Page 12

Operating Instructions 

2. CONVOTHERM PC-HACCP 

 page 

 

 

10 July 2006 

 

CONVOTHERM PC-HACCP 

 

 

2.4.2 Checking HACCP Criteria 

1. Click 

File

 while the CONVOTHERM PC-HACCP program is running.

 

2. Click

 Open

3.  Click the directory named 

ACTUAL

.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.  Click the desired Daily File. 

 

 

 

 

 

 

 

 

 

 

 

 

 

The 

List of 

cooking cycles

 window shows cooking process information. 

 

Summary of Contents for Convotherm PC-Control

Page 1: ...260AZV REV B 7 06 Operating Instructions CONVOTHERM PC Control CONVOTHERM PC HACCP 1333 East 179th Street Cleveland Ohio 44110 Phone 216 481 4900 1 800 338 2204 Fax 216 481 3782 www clevelandrange com...

Page 2: ...king Up HACCP Data 2 3 Assigning HACCP Criteria to Programs Recipes 2 4 Making HACCP Criteria Is Fulfilled 2 4 1 Online Check 2 4 2 Checking HACCP Criteria 3 CONVOTHERM PC Control 3 1 Software Install...

Page 3: ...m PC Control software can store up to 250 recipes The recipes can be transferred to all your networked Combis in seconds Recipes can be deleted copied or changed as needed Stored recipes and functions...

Page 4: ...ware on a PC 1 Start Windows 95 or Windows NT on the PC 2 End all other programs before installing the Convotherm software 3 Insert the installation CD ROM into the CD ROM drive 4 Use Windows Explorer...

Page 5: ...In Network 1 choose a COM port Most computers use COM1 for RS232 The USB network COM selection will depend on the software included with the USB Network adapter 4 In Network 2 choose a second COM port...

Page 6: ...l to the Setup icon it looks like an oven 3 Press the Smart Key for YES 4 Scroll to the Network Address icon it looks like three computers tied together 5 Enter the address of the Combi The first Comb...

Page 7: ...ck on Connect 4 Select the Network Address N1 N2 etc of the Combi in the Address scroll window 5 Enter a Unit name First oven shown 6 In connected with click Network 1 or Network 2 7 Click the connect...

Page 8: ...PC HACCP page 5 10 July 2006 CONVOTHERM PC HACCP 9 The Combi icon is displayed with its unit name First o shown 10 When a Combi is connected with the software its icon changes from dark grey to a lig...

Page 9: ...onth_year HCP 18_10_05 HCP shown 4 As soon as a Program is finished it is automatically stored Brief cooking periods can be excluded from storage by using a Time Filter Time Filter Note Any cooking pr...

Page 10: ...rams Instead use the same number for the same Program in ALL the networked Combis for a maximum of 250 Program numbers In the CONVOTHERM PC HACCP software HACCP criteria can be allocated using these P...

Page 11: ...be viewed for any Combi at any time providing the ability to check every cooking process As soon as a cooking process has finished it is automatically stored in the Daily File The Daily File can be v...

Page 12: ...06 CONVOTHERM PC HACCP 2 4 2 Checking HACCP Criteria 1 Click File while the CONVOTHERM PC HACCP program is running 2 Click Open 3 Click the directory named ACTUAL 4 Click the desired Daily File The Li...

Page 13: ...OK HACCP criteria were fulfilled xx HACCP criteria were not fulfilled Manual Program was used no stored Program Date 12 7 1998 Unit Cycle Start End Prg No HACCP Recipe 1 01 9 55 10 05 202 Bread roll 2...

Page 14: ...otes window 2 Add notes to cooking cycle data 3 Click add 4 Click OK to save or Cancel to quit without saving Print Click Print The contents of the current window are printed The contents of the Notes...

Page 15: ...the parallel printer interface LPT 2 Install the PC Control software using the same procedure as the PC HACCP software 3 For easier Program startup place a shortcut to the PC CONTROL EXE on the deskto...

Page 16: ...ate opens 2 Select an operating mode by left clicking an icon The Cook Hold mode cannot be selected in the first step and is grey 3 After selecting the desired operating mode the default values appear...

Page 17: ...rrent step is completed After complete input of a step the other steps can be viewed by clicking on the cardfile card tab with the step number A maximum of 9 steps can be entered The total time of a P...

Page 18: ...lick to print a Program To Program HACCP CRITERIA 1 Click on the HACCP button in the Programming window 2 Click on CT core temperature and or Oven 3 If required change the default values with the arro...

Page 19: ...red value in the field Cook Hold Cook Hold Programs automatically switch from the Cook phase to the Hold phase when the set Time or Core Temperature is reached Select Hold Temperature so the cooking c...

Page 20: ...3 Select the directory for the new Cookbook 4 Enter the file name 5 Click Save or use Cancel to quit without saving Note When starting the CONVOTHERM PC Control software the original Program file Prg...

Page 21: ...ting with OK or use Cancel to quit without printing 3 3 5 Sort Lists The lists can be sorted in ascending or descending order by clicking the list headings Sorting can be done by Program number Progra...

Page 22: ...ft hand area of the window A Program can be sent to a Combi by clicking on the Status icon 1 Select transmission type Send Send Start Send Autostart o When using Send Autostart set the time informatio...

Page 23: ...essing the Shift key Single non consecutive Program numbers by pressing the Ctrl key If Programs are to be sent to all the registered Combis these can be marked with the Select all button Notes If no...

Page 24: ...in the Combis 3 5 2 Enable or Disable Controls on a Combi Disable 1 Click Options 2 Click Locking out control panel 3 Click the controls to be disabled The disabled controls turn grey with grey symbo...