The installation instructions must be read in their entirety before starting the installation of this steamer.
•
To install this steamer, the following requirements must be considered when selecting a location.
a.
A suitable drain must be available within 12 ft. of the steamer. Do NOT install the appliance directly
over a drain. Steam rising out of the drain will adversely affect operation, hamper cooling air
circulation, and damage electrical and electronic components. NOTE: The drain MUST NOT be
located beneath the steamer itself.
b.
An electrical supply matching the power requirements found on the rating plate must be available,
which is not of the GFCI (Ground Fault Interrupter Circuit) type.
c.
A gas supply matching the fuel requirements found on the rating plate must be available.
d.
The location must have sufficient space to meet the clearance requirements of the steamer as
outlined in Chapter 2, Section B, Part 1, “Locating the Steamer”.
e.
A water supply meeting the requirements outlined in Chapter 2, Sectio
n B, Part 6 “Water Supply
Requirements and Installation” must be available.
B. INSTALLATION OF THE STEAMER
After selecting the steamer’s operating location, the steamer can be positioned, and installed.
1.
Locating the Steamer
a.
Location and Clearance Requirements of the Steamer
For safe and efficient operation, observe the following criteria when selecting an operating location
for the Gemini steamer.
1)
The unit should be installed in an area that is free and clear of combustible materials.
2)
Do NOT install the appliance directly over a drain. Steam rising up out of the drain will
adversely affect operation, hamper cooling air circulation, and damage electrical and
electronic components.
3)
A proper air supply for combustion and ventilation is critical to safe, efficient operation of Gemini
gas steamers.
4)
Do not install any heat producing equipment near the air vents of the equipment. Do not block
the air vents of the unit. Do not store articles on top of the unit.
WARNING
DO NOT INSTALL a Gemini steamer that has been damaged.
Install the Gemini steamer according to the policies and procedures
outlined in this manual.
WARNING
All clearance requirements above, below, and around the unit are
the same for non-combustible locations as for combustible
locations.
CAUTION
Malfunctions and equipment damage may result from improper
mounting. Malfunctions and/or damage resulting from improper
mounting are not covered by the equipment warranty.
The steamer MUST BE LEVEL BOTH FRONT TO BACK AND
SIDE TO SIDE in all mounting arrangements.
Catastrophic damage will result from shifting the steamer more than
10
o
out of level with power supplied to the unit.