July
2020
General Notes
Note 1:
Standard screws shipped for Tin Roof Interfaces
Metal Purlins/Battens Fasteners
to
use
0.75 mm
Buildex- 14 - 11 x 70 Hex Head Zips Climaseal 3 with 16 mm
ABW on G550 Steel Battens
1.9 mm - 2.4 mm
Buildex- 14 - 11 x 70 Hex Head Zips Climaseal 3 with 16 mm
ABW
Wood Purlins and Rafters
Fasteners to be used
Timber F7 (Pine) and Timber 17
(Hardwood). 25 mm, 30 mm and
35 mm embedment
Buildex- 14 - 11 x 70 Hex Head Zips Climaseal 3 with 16 mm
ABW or 14g (6.3 mm)
Note 2:
Tin spacings were calculated based on Steel Purlins G450 1.9mm.
Note 3.
This Engineering Document was designed to cater for most common installation scenarios
however, it does not cater for all of them. Contact Clenergy if you are unable to comply with any of
the installation specifications listed on this document.
Note 4.
The following components are satisfied for use according to AS/NZS 1664.1:1997-Amdt
1:1999 and AS/NZS 1170.2:2011 Amdt 4-2016.
Components
Part No.
Description
ECO-Rail
ER-R-ECO/XXXX
ECO Rail
Splice
ER-SP-ECO
PV-ezRack Splice for ECO
rail
Australian Made
Mill Finish ECO Rail
R-ECO/XXXX/AUMF
PV-ezRack Australian
Made Mill Finish ECO Rail
ST-Rail
ER-R-STXXXX
Standard Rail
Splice
ER-SP-ST
PV-ezRack Splice for
Standard Rail 200mm
T50 Rail
ER-R-T50/XXXX
T50 Rail