5.4.4 Insert the Ground Clip (EZ-GC-ST)
between Cable Tray and ECO Rail for each
fixing point, as shown in Figure 17.
Note: when using cutter rail (mill finish
ECO rail), grounding clip is not necessay.
5.4.5 Fasten all M8 bolts with the
recommended toque of 15-17N·m.
Note: Check the electrical resistance
between ECO rail and cable tray to ensure
the bonding is made.
5.4.6 Align and click MT-rail cable tray cover