Page 11
© 2021 CLEMCO INDUSTRIES CORP.
www.clemcoindustries.com
Manual No. 30423
3.3.2
Combine the table assembly and track by sliding
the table assembly rollers into the track channels, as
shown in Figure 8.
NOTE: If the weight of the table and track make it too
heavy to install as an assembly, the track may be placed
in the cabinet to predrill mounting holes, but the table
must also be in place within the rails before fasteners
are installed.
3.3.3
Refer to Figure 9 and center the track and table
assembly inside the cabinet on top of the grate. Make
sure the two angled mounting brackets are facing toward
the door from which the table will slide.
Figure 9
3.3.4
Match drill two 1/2" diameter holes on each side
of the cabinet, using the holes in the mounting brackets
as a template. NOTE: To prevent the track from shifting,
temporarily place a 3/8-NC x 1-1/2" bolt through each
hole after it is drilled.
3.3.5
After the holes are drilled and the table
assembly is placed in the track rails, secure all
fasteners.
Figure 10
3.4
U-Tube Manometer
The manometer is used to measures reclaimer static
pressure and optional HEPA-Filter differential pressure.
The optional manometer is listed in Section 10.1
3.4.1
Consistent reclaimer static-pressure is necessary
for precise media separation, as the reclaimer's
efficiency is achieved by a centrifugal balance of air flow,
particle weight, and size. Reclaimer static pressure is set
by adjusting the dust-collector exhaust damper; refer to
Section 5.4 to adjust static pressure. Refer to Section 5.10
for using the manometer to set reclaimer static pressure.
3.5
HEPA Afterfilter
3.5.1
Installation and operating instructions are provided
with the HEPA Filter.
4.0
OPERATION
4.1
Season Filter Cartridge
Do not pulse a new dust collector or
replacement filter cartridge until the cartridge is
properly seasoned, per Section 7.13.
Pulsing unseasoned cartridges can decrease
the efficiency of the dust collector and cause
premature cartridge failure.
4.2
Media Loading and Media Capacity – Figure 11
4.2.1 Media capacity:
The approximate capacity and
minimum media amount is shown in the table below.
Reclaimer Size Minimum Wt. Capacity
300 cfm
10 lbs
50 lbs (0.5 cuft)
4.2.2 Media loading:
Refill only after all media has
been recovered from the cabinet.
Do not pour
media directly into the cabinet hopper, as
overfilling may occur.
Overfilling results in media
carryover to the dust collector and possible blockage in
the conveying hose.
1. Turn OFF the exhauster.
2. Unhook the two door latches and open the reclaimer
fill door.
Match Drill
Match Drill
Angled Mount Brackets
Slide table to center or as
needed to position part for
blasting.
Slide table out for ease
of loading part(s). Not
to exceed 500 pounds.