PULSAR
®
3D SUCTION BLAST CABINET
Page 17
© 2020 CLEMCO INDUSTRIES CORP.
www.clemcoindustries.com
Manual No. 29374
Figure 19
6.9.2
Reconnect the tubing by inserting it into the
retaining collar until it seats. Tug on the tubing to make
sure it is secured.
6.10
Replace Reclaimer Wear Plate
– Figure 20
6.10.1
Remove the fasteners holding the reclaimer top
to the body and remove the top.
6.10.2
The gasket should adhere to the reclaimer when
the top is removed. Inspect the gasket and replace it if
damaged.
6.10.3
Remove the screws that hold the wear plate to
the body and remove the old wear plate.
6.10.4
Press or clamp the new wear plate into position
and use self-drilling screws inserting through the existing
screw holes to secure the wear plate.
6.10.5
Replace the top and secure with fasteners.
Figure 20
7.0
TROUBLESHOOTING
To avoid serious injury, observe the following
when troubleshooting:
Turn OFF the compressed-air supply,
bleed the supply line, lockout, and tagout
the air supply.
If checking the controls requires air, always
enlist the aid of another person to:
•
Hold the blast gun securely.
•
Operate the foot pedal.
Never bypass the foot pedal or wedge it in
the operating position.
Never bypass the door interlock system.
Follow all OSHA regulations, including
lockout and tagout procedures.
7.1
Poor visibility
7.1.1
Dirty filter cartridge. Empty the dust container.
Pulse cartridge several times, per Section 5.2.4. Inspect
cartridge and replace when necessary.
7.1.2
Exhauster motor not operating. Check voltage to
motor and motor wiring.
7.1.3
Using friable media that rapidly breaks down, or
using media that is too fine or worn out. Check condition
of media.
7.1.4
Reclaimer door open. Check door.
7.1.5
Hole worn in flex hose between cabinet hopper
and reclaimer inlet, or reclaimer outlet and dust collector
inlet. Replace hose.
7.1.6
Obstruction in flex hose between the cabinet
hopper and reclaimer inlet. Inspect hose for blockage.
7.2
Abnormally High Media Consumption
7.2.1
Door on reclaimer open or improper fit, or worn
door gasket. Air entering the reclaimer at this point will
cause media to be carried into the dust collector. DO NOT
operate unless all doors are closed.
7.2.2
Reclaimer slide door open. Refer to Section 4.6
to adjust slide door.
7.2.3
Media may be too fine or worn-out. Refer to
Section 1.8 for recommended media size.
Retaining Collar
Push collar in to release tubing.
Pull tubing straight out.
To reconnect the tubing, push it into the
fitting until it bottoms out. Pull on the tubing
to make sure it is securely fastened.
Wear Plate
Gasket
Self-Drilling Screws
Reclaimer Top
Clamp
Shown for reference.