Apex Tool Group
TM12-1109 |
2019-02
11
1
EN
7
Troubleshooting
Malfunction
Possible causes
Remedy
Tool does not start
Faulty start switch
Replace start switch
No speed (RPM) pro-
grammed
Program speed for all active stages
Controller waiting for tool
enablement
Activate input
Tool Enable
or, if not
required Deactivate
Tool Enable
Faulty cable
Repair or replace cable
Bent pins in cable or tool
Straighten contact pins or replace
faulty connector
Self identification data not
recognized after tool change
Accept
Data
again (Tool Setup)
Tool not recognized
Software incorrect
Check controller software / measur-
ing board software
Cable defective
Replace cable
Tool defective
Change tool
Tool doesn't start with coun-
terclockwise rotation acti-
vated
With counterclockwise rota-
tion, parameter for speed is
set to 0 rpm.
Check multi-function button assign-
ments
Tool starts in tightening
direction, but not in counter-
clockwise rotation
No speed programmed for
counterclockwise rotation
Program speed for counterclockwise
rotation
Faulty reverse switch
Replace Start/Reverse switch
assembly
Faulty cable
Repair or replace cable
Bent pins in cable or tool
Check multi-function button assign-
ments
Tool shuts off at desired
torque but without angle
indicator
Threshold torque is too high
Correct fastening sequence or
reduce threshold torque value
Tool shuts off prematurely
Operator releases start
switch before the controller
stops the tool
Make sure that the operator keeps
the start switch pressed throughout
the entire sequence.
The fastening time exceeds
the standard time by 10 sec-
onds.
Increase the fastening time
Tool exceeds the angle set-
point
Check the fastening sequence to
ensure that the torque shutoff value
and/or angle setpoint are correct.
Adjust as necessary.
Check whether the fastening joint
has changed significantly.
Tool does not change speed
Speed is the same in all
stages
Make sure that the speed and the
switching angle in the stages are
correct.
LEDs on the tool start to
flash when the reverse
switch is operated
This is a normal function
which is defined in the
default parameters.
Activate or deactivate the check box
Blink Lights when Tool in Reverse
Summary of Contents for NeoTek 30 Series
Page 26: ...Leistungsdaten 26 TM12 1109 LG1 2019 02 Apex Tool Group 2 DE...
Page 38: ...Datos de rendimiento 38 TM12 1109 LG1 2019 02 Apex Tool Group 3 ES...
Page 50: ...Caract ristiques techniques 50 TM12 1109 LG1 2019 02 Apex Tool Group 4 FR...
Page 62: ...Prestazioni 62 TM12 1109 2019 02 Apex Tool Group 5 IT...
Page 75: ......